Feasibility Assay for Measure of Sternocleidomastoid and Platysma Electromyography Signal for Brain-Computer Interface Feedback
Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=51353#.VGVhA2fHRK0
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=51353#.VGVhA2fHRK0
Author(s)
A feasibility assay is conducted for
electromyography measure in sternocleidomastoid and platysma, tenting to
use it on Brain-Computer Interface (BCI) feedback. It is proposed a
case of study for four healthy subjects with an average of 35 years old,
two females and two males. Methodology proposed includes signal
acquisition and processing with feature extraction of RMS, Mean and
Variance. The data are acquired with the AD board NI USB-6009,
interfaced with LabView and processed in MatLab. An uncertainty analysis
was made obtaining a system uncertainty of ±2.31 mV. ANOVA analysis was
done, with a Randomized Complete Block Design (RCBD) experiment and
interaction of factors and residues obtained with the software Minitab.
KEYWORDS
Cite this paper
Galego, J. , Casas, O. and Balbinot, A. (2014)
Feasibility Assay for Measure of Sternocleidomastoid and Platysma
Electromyography Signal for Brain-Computer Interface Feedback. Intelligent Control and Automation, 5, 253-261. doi: 10.4236/ica.2014.54027.
[1] | Peter, K. (2005) ABC of EMG: A Practical Introduction to Kinesiological Electromyography. Noraxon INC, USA. |
[2] | Xinyi, Y., Rabab, K.W. and Gary, E.B. (2008) Facial EMG Contamination of EEG Signals: Characteristics and Effects of Spatial Filtering. Proceedings of the ISCCSP 2008, Ottawa, 12-14 March 2008, 729-734. |
[3] | Teena, G., Shalu, G.K. and Sivanandan, K.S. (2011) Processing and Application of EMG signals for HAL (Hybrid Assistive Limb). Proceedings of the 2nd International Conference on Sustainable Energy and Intelligent System (SEISCON 2011), Chennai, 20-22 July 2011, 749-753. |
[4] | Kazuo, K. and Yoshiaki, H. (2011) Motion Estimation Based on EMG and EEG Signals to Control Wearable Robots. Proceedings of the 2013 IEEE International Conference on Systems, Man, and Cybernetics, Japan, 4213-4218. |
[5] | Elaine, A.C., Nicholas, A.S. and Eric, J.P. (2013) EMG Control of Robotic Reaching by People with Tetraplegia Improved through Proprioceptive and Force Feedback. Proceedings of the 6th Annual International IEEE EMBS Conference on Neural Engineering, San Diego, 6-8 November 2013, 1178-1181. |
[6] | Douglas, C.M. (2013) Randomized Blocks, Latin Squares, and Related Designs. In: Design and Analysis of Experiments, 8th Edition, John Wiley & Sons, Inc., Hoboken, 139-146. |
[7] |
Calibration of Measuring Devices
for Electrical Quantities Calibration of Oscilloscopes. EURAMET
(European Association of National Metrology Institutes) cg-7, Version
1.0 (06/2011). Calibration Guide. Bundesallee 100, D-38116 Braunschweig,
Germany. http://www.euramet.org/ |
[8] | Balbinot, A. and Favieiro, G. (2013) A Neuro-Fuzzy System for Characterization of Arm Movements. Sensors, 13, 2613-2630. |
[9] | Tektronix (1998) Measurement Products Catalog 1998/1999, Tektronix. |
[10] | (2012) USER GUIDE AND SPECIFICATIONS NI USB-6008/6009: Bus-Powered Multifunction DAQ USB Device, National Instruments. eww141114lx |