Read full pape at: http://www.scirp.org/journal/PaperInformation.aspx?PaperID=47481#.VFm6fGfHRK0 Author(s) Adam Martin , Lucius Akalanne Affiliation(s) Wireless R&D, Alcatel Lucent, Swindon, United Kingdom . Wireless R&D, Alcatel Lucent, Swindon, United Kingdom . ABSTRACT Passive cooling techniques are cost effective and reliable methods of cooling remote radio heads (RRH). This paper investigates the plausibility of a passive cooling technique involving exchanging warm air, from the internal cavity of RRHs, with fresh ambient air, to reduce the operating temperature using natural convection across air filters. The results indicate that, an internal air filter tube structure, with widt...