Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=52987#.VK86BMnQrzE
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=52987#.VK86BMnQrzE
Affiliation(s)
1Engineering and Manufacturing Division, Iran Sanaat Industrial Group, Shiraz, Iran.
2School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
3Department of Engineering, Aliabad Katoul Branch, Islamic Azad University, Aliabad Katoul, Iran.
4Department of Engineering, Bushehr Branch, Islamic Azad University, Bushehr, Iran.
2School of Mechanical Engineering, Shiraz University, Shiraz, Iran.
3Department of Engineering, Aliabad Katoul Branch, Islamic Azad University, Aliabad Katoul, Iran.
4Department of Engineering, Bushehr Branch, Islamic Azad University, Bushehr, Iran.
ABSTRACT
This
paper reports on the modeling and simulation of flashing-induced
instabilities in naturalcirculation systems, with special emphasis on
simplified boiling water reactors (SBWRs). In this work, flashing-induced oscillations have been
studied by using an experimental test facility (SIRIUS-N) and
RELAP5/MOD3.2 thermal hydraulic code. The behavior of the test facility
is investigated for different values of core inlet temperature value.
The results of the simulations have been compared qualitatively and
quantitatively with experiments. In general, deviations are found
between the numerical and experimental results, in spite of the close
similarity between the SIRIUS-N facility and the definition of the
system in the RELAP code. This result indicates that predictions
regarding experimental facility, based on modeled system, should be
carefully considered.
KEYWORDS
Cite this paper
References
Atajafari,
H. , Nematollahi, M. , Hashemi-Tilehnoee, M. and Rafiee, N. (2015)
Validation of RELAP5/MOD3.2 Code for Flashing-Induced Instabilities in a
Single Channel. World Journal of Nuclear Science and Technology, 5, 6-17. doi: 10.4236/wjnst.2015.51002.
| [1] | Inada,
F., Furuya, M. and Yasuo, A. (2000) Thermo-Hydraulic Instability of
Boiling Natural Circulation Loop Induced by Flashing (Analytical
Consideration). Nuclear Engineering and Design, 200, 187-199. http://dx.doi.org/10.1016/S0029-5493(99)00334-9 |
| [2] | De Kruijf, W.J.M., Van der Hagen, T.H.J.J. and Mudde, R.F. (1999) CIRCUS, a Natural Circulation Two-Phase Flow Facility. Proceeding of the Eurotherm Seminar No. 63. |
| [3] | Van
Bragt, D.D.B., De Kruijf, W.J.M., Manera, A., Van Der Hagen, T.H.J.J.
and Van Dam, H. (2002) Analytical Modeling of Flashing-Induced
Instabilities in a Natural Circulation Cooled Boiling Water Reactor.
Nuclear Engineering and Design, 215, 87-98. http://dx.doi.org/10.1016/S0029-5493(02)00043-2 |
| [4] | Furuya,
M., Inada, F. and Van der Hagen, T.H.J.J. (2005) Flashing-Induced
Density Wave Oscillations in a Natural Circulation BWR—Mechanism of
Instability and Stability Map. Nuclear Engineering and Design, 235,
1557-1559. http://dx.doi.org/10.1016/j.nucengdes.2005.01.006 eww150109lx |
| [5] | Andersen, J.G.M., Inada, F. and Klebanov, L.A. (1995) TRACG Analyses of Flashing Instability during Start-Up. Proceedings of the 3rd International Conference on Nuclear Engineering ICONE-3, Kyoto, 23-27 April 1995. |