Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=48988#.VJd83cCAM4
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=48988#.VJd83cCAM4
Author(s)
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy.
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy.
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy.
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy.
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy.
Laboratory of Industrial Environment Engineering, Ecole des Mines d’Alès, Alès cedex, France.
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy.
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy.
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy.
Department of Chemistry, Materials and Chemical Engineering “Giulio Natta”, Politecnico di Milano, Milano, Italy.
Laboratory of Industrial Environment Engineering, Ecole des Mines d’Alès, Alès cedex, France.
The
ammonia loss through NalophanTM bags has been studied. Ammonia was
chosen as target compound in order to be representative of odorous molecules of
small dimensions. The losses observed for storage conditions and times as
allowed by the reference standard for dynamic olfactometry (EN 13725:2003)
indicate that odour concentration values due to the presence of small molecules
may be significantly underestimated if samples are not analysed immediately
after sampling. The diffusion coefficient of ammonia through the NalophanTM film was evaluated using the Fick’s law, and it turned out to be equal to 2.38E-12 (m2/s). The results and their theoretical
interpretation indicate that concentration losses due to ammonia diffusion
through the NalophanTM film can be decreased by using large bags and
filling them up to their maximum capacity.
KEYWORDS
Cite this paper
Sironi, S. , Eusebio, L. , Capelli, L. , Boiardi, E.
, Rosso, R. and Guillot, J. (2014) Ammonia Diffusion Phenomena
through NalophanTM Bags Used for Olfactometric Analyses. Journal of Environmental Protection, 5, 949-961. doi: 10.4236/jep.2014.511096.
| [1] | Capelli, L., Sironi, S., Del
Rosso, R., Centola, P., Rossi, A. and Austeri, C. (2011) Olfactometric
Approach for the Evaluation of Citizens’ Exposure to Industrial
Emissions in the City of Terni, Italy. Science of the Total Environment,
409, 595-603. http://dx.doi.org/10.1016/j.scitotenv.2010.10.054 |
| [2] | Nicell, J.A. (2009) Assessment
and Regulation of Odour Impacts. Atmospheric Environment, 43, 196-206. http://dx.doi.org/10.1016/j.atmosenv.2008.09.033 |
| [3] | Schulz, T.J. and Harreveld,
A.P.V. (1996) International Moves towards Standardisation of Odour
Measurement Using Olfactometry. Water Science and Technology, 34,
541-547. http://dx.doi.org/10.1016/0273-1223(96)00594-X |
| [4] | Sironi, S. and Botta, D. (2001)
Biofilter Efficiency in Odor Abatement at Composting Plants. Compost
Science & Utilization, 9, 149-155. http://dx.doi.org/10.1080/1065657X.2001.10702029 |
| [5] | Capelli, L., Sironi, S., Del
Rosso, R., Centola, P. and Bonati, S. (2010) Improvement of
Olfactometric Measurement Accuracy and Repeatability by Optimization of
Panel Selection Procedures. Water Science and Technology, 61, 1267-1278.
http://dx.doi.org/10.2166/wst.2010.023 |
| [6] | Bokowa, A.H. (2008) The Effect of Sampling on the Measured Odour Concentration. Chemical Engineering Transactions, 23, 43-48. |
| [7] | Bourgeois, W., Romain, A.C.,
Nicolas, J. and Stuetz, R.M. (2003) The Use of Sensor Arrays for
Environmental Monitoring: Interests and Limitations. Journal of
Environmental Monitoring, 5, 852-860. http://dx.doi.org/10.1039/b307905h |
| [8] | Laor, Y., Ozer, Y., Ravid, U., Hanan, A. and Orenstein, P. (2010) Methodological Aspects of Sample Collection for Dynamic Olfactometry. Chemical Engineering Transactions, 23, 55-60. |
| [9] | Kim, Y.-H. and Kim, K.-H. (2012)
Experimental Approach to Assess Sorptive Loss Properties of Volatile
Organic Compounds in the Sampling Bag System. Journal of Separation
Science, 35, 2914-2921. http://dx.doi.org/10.1002/jssc.201200388 |
| [10] | CEN (2003) EN13725 Air Quality—Determination of Odour Concentration by Dynamic Olfactometry. Comite Europe en de Normalisation (CEN), Brussels. |
| [11] | van Harreveld, A.P. (2003) Odor
Concentration Decay and Stability in Gas Sampling Bags. Journal of the
Air & Waste Management Association, 53, 51-60. http://dx.doi.org/10.1080/10473289.2003.10466121 |
| [12] | Juarez-Galan, J.M., Martinez, J.V., Amo, A. and Valor, I. (2008) Background Odour from Sampling Bags. Influence on the Analysis of Odour Concentration. Chemical Engineering Transactions, 15, 87-94. |
| [13] | van Harreveld, A.P., Heeres, P. and Harssema, H. (1999) A Review of 20 Years of Standardization of Odor Concentration Measurement by Dynamic Olfactometry in Europe. Journal of the Air & Waste Management Association, 49, 705-715. |
| [14] | Guillot, J.M. and Beghi, S. (2008) Permeability to Water Vapour and Hydrogen Sulphide of Some Sampling Bags Recommended by EN 13725. Chemical Engineering Transactions, 15, 79-86. |
| [15] | Ghosh, S., Kim, K.H. and Sohn,
J.R. (2011) Some Insights into Analytical Bias Involved in the
Application of Grab Sampling for Volatile Organic Compounds: A Case
Study against Used Tedlar Bags. The Scientific World Journal, 11,
2160-2177. http://dx.doi.org/10.1100/2011/529532 |
| [16] | Wang, C., Lai, P.C., Syu, S.H.
and Leu, J. (2011) Effects of CF4 Plasma Treatment on the Moisture
Uptake, Diffusion, and WVTR of Poly(ethylene terephthalate) Flexible
Films. Surface and Coatings Technology, 206, 318-324. http://dx.doi.org/10.1016/j.surfcoat.2011.07.026 |
| [17] | Koziel, J.A., Spinhirne, J.P.,
Lloyd, J.D., Parker, D.B., Wright, D.W. and Kuhrt, F.W. (2005)
Evaluation of Sample Recovery of Malodorous Livestock Gases from Air
Sampling Bags, Solid-Phase Microextraction Fibers, Tenax TA Sorbent
Tubes, and Sampling Canisters. Journal of the Air & Waste Management
Association, 55, 1147-1157. http://dx.doi.org/10.1080/10473289.2005.10464711 |
| [18] | Cariou, S. and Guillot, J.M.
(2006) Double-Layer Tedlar Bags: A Means to Limit Humidity Evolution of
Air Samples and to Dry Humid Air Samples. Analytical and Bioanalytical
Chemistry, 384, 468-474. http://dx.doi.org/10.1007/s00216-005-0177-4 |
| [19] | Trabue, S.L., Anhalt, J.C. and
Zahn, J.A. (2006) Bias of Tedlar Bags in the Measurement of Agricultural
Odorants. Journal of Environmental Quality, 35, 1668-1677. http://dx.doi.org/10.2134/jeq2005.0370 |
| [20] | Mochalski, P., Wzorek, B.,
Sliwka, I. and Amann, A. (2009) Suitability of Different Polymer Bags
for Storage of Volatile Sulphur Compounds Relevant to Breath Analysis.
Journal of Chromatography B: Analytical Technologies in the Biomedical
and Life Sciences, 877, 189-196. http://dx.doi.org/10.1016/j.jchromb.2008.12.003 |
| [21] | Parker, D.B.,
Perschbacher-Buser, Z.L., Cole, N.A. and Koziel, J.A. (2010) Recovery of
Agricultural Odors and Odorous Compounds from Polyvinyl Fluoride Film
Bags. Sensors, 10, 8536-8552. http://dx.doi.org/10.3390/s100908536 |
| [22] | Hansen, M.J., Adamsen, A.P.S.,
Feilberg, A. and Jonassen, K.E.N. (2011) Stability of Odorants from Pig
Production in Sampling Bags for Olfactometry. Journal of Environmental
Quality, 40, 1096-1102. http://dx.doi.org/10.2134/jeq2010.0497 |
| [23] | Sironi, S., Eusebio, L.,
Dentoni, L., Capelli, L. and Del Rosso, R. (2014) Ammonia Diffusion
through NalophanTM Bags. Water Science and Technology, 69, 486-494. http://dx.doi.org/10.2166/wst.2013.700 |
| [24] | Sulyok, M., Haberhauer-Troyer,
C., Rosenberg, E. and Grasserbauer, M. (2001) Investigation of the
Storage Stability of Selected Volatile Sulfur Compounds in Different
Sampling Containers. Journal of Chromatography A, 917, 367-374. http://dx.doi.org/10.1016/S0021-9673(01)00654-9 |
| [25] | Sulyok, M., Haberhauer-Troyer,
C. and Rosenberg, E. (2002) Observation of Sorptive Losses of Volatile
Sulfur Compounds during Natural Gas Sampling. Journal of Chromatography
A, 946, 301-305. http://dx.doi.org/10.1016/S0021-9673(01)01541-2 |
| [26] | Kim, K.H. (2006) A Study of
Sorptive Loss Patterns for Reduced Sulfur Compounds in the Use of the
Bag Sampling Method. Environmental Monitoring and Assessment, 123,
259-269. http://dx.doi.org/10.1007/s10661-006-9195-8 |
| [27] | Kim, K.H., Choi, G.H., Choi,
Y.J., Song, H.N., Yang, H.S. and Oh, J.M. (2006) The Effects of Sampling
Materials Selection in the Collection of Reduced Sulfur Compounds in
Air. Talanta, 68, 1713-1719. http://dx.doi.org/10.1016/j.talanta.2005.08.037 |
| [28] | Saìz, J., Ferrando, J.L.,
Atoche, J.C., Torre, M. and Ruiz, C.G. (2011) Study of Losses of
Volatile Compounds from Dinamite. Investigation of Cross-Contamination
between Dynamites Stored in Polyethylene Bags. Forensic Science
International, 211, 27-33. http://dx.doi.org/10.1016/j.forsciint.2011.04.007 |
| [29] | Jo, S.H., Kim, K.H., Shon, Z.H.
and Parker, D. (2012) Identification of Control Parameters for the
Sulfur Gas Storability with Bag Sampling Methods. Analytica Chimica
Acta, 738, 51-58. http://dx.doi.org/10.1016/j.aca.2012.06.010 |
| [30] | Kim, Y.H., Kim, K.H., Jo, S.H.,
Jeon, E.C., Sohn, J.R. and Parker, D.B. (2012) Comparison of Storage
Stability of Odorous VOCs in Polyester Aluminum and Polyvinyl Fluoride
Tedlar (R) Bags. Analytica Chimica Acta, 712, 162-167. http://dx.doi.org/10.1016/j.aca.2011.11.014 |
| [31] | Crank, J. and Park, G.S. (1968) Diffusion in Polymers. 1st Edition, Academic Press, London and New York. |
| [32] | Beghi, S. and Guillot, J.M.
(2006) Sample Water Removal Method in Volatile Organic Compound Analysis
Based on Diffusion through Poly(vinyl fluoride) Film. Journal of
Chromatography A, 1127, 1-5. http://dx.doi.org/10.1016/j.chroma.2006.05.102 |
| [33] | Beghi, S. and Guillot, J.M.
(2008) Use of Poly(ethylene terephthalate) Film Bag to Sample and Remove
Humidity from Atmosphere Containing Volatile Organic Compounds. Journal
of Chromatography A, 1183, 1-5. http://dx.doi.org/10.1016/j.chroma.2007.12.051 |
| [34] | Igwe, I.O., Ewulonu, C.M. and
Igboanugo, I. (2006) Studies on the Diffusion Characteristics of Some
Aromatic Solvents into Polypropylene Film. Journal of Applied Polymer
Science, 102, 1985-1989. http://dx.doi.org/10.1002/app.24593 |
| [35] | Mallia, I. (2010) Sviluppo di una nuova metodologia per la misura della permeabilita di film plastici ad uso alimentare. Thesys Dissertation, Universita degli studi di Catania, Catania. |
| [36] | Piergiovanni, L. and Limbo, S. (2010) Proprieta chimiche dei materiali di packaging. Food packaging, Springer-Verlag, Milan. |
| [37] | Akdeniz, N., Janni, K.A.,
Jacobson, L.D. and Hetchler, B.P. (2011) Comparison of Gas Sampling Bags
to Temporarily Store Hydrogen Sulfide, Ammonia, and Greenhouse Gases.
Transactions of the ASABE, 54, 653-661. http://dx.doi.org/10.13031/2013.36468 eww141222lx |
评论
发表评论