ABSTRACT
The
primary purpose of this paper is to provide a novel wavelet-domain
method for digital radiography with low dose examination. Approach of
this study is an improved wavelet-transform-based method for potentially
reducing radiation dose while maintaining clinically acceptable image
quality. The wavelet algorithm integrates the advantages of
wavelet-coefficient-weighted method and the existing Bayes Shrink
thresholding method. In order to confirm the usefulness of the proposed
method, the resolving and noise characteristics of the processed
computed radiography images were measured. In addition, variations of
contrast and noise with respect to radiation dose were also examined.
Finally, to verify the effect of clinical examination, visual
evaluations were also performed in lower abdominal area using phantom.
Our quantitative results demonstrated that our wavelet algorithm could
improve resolution characteristics while keeping the noise level within
acceptable limits. Visual evaluation result demonstrated that the
proposed method was superior to other published methods. Our proposed
method recognized effect on decreasing in exposure dose in lower
abdominal radiographs. As a conclusion, our proposed method’s
performance is better when compared with that of the 3 conventional
methods. The proposed method has the potential to improve visibility in
radiographs when a lower radiation dose is applied.
Cite this paper
References
Watanabe,
H. , Tsai, D. , Lee, Y. and Matsuyama, E. (2015) Dose Reduction by the
Use of a Wavelet-Based Denoising Method for Digital Radiography. Health, 7, 220-230. doi: 10.4236/health.2015.72026.
| [1] | Gruber,
M., Weber, M., Homolka, P., Nemec, S., Fruehwald-Pallamar, J. and
Uffmann, M. (2011) Feasibility of Dose Reduction Using Needle-Structured
Image Plates versus Powder-Structured Plates for Computed Radiography
of the Knee. American Journal of Roentgenology, 197, 318-323. http://dx.doi.org/10.2214/AJR.10.5505 |
| [2] | Liu,
X., Shaw, C.C., Lai, C.J. and Wang, T. (2011) Comparison of Scatter
Rejection and Low-Contrast Performance of Scan Equalization Digital
Radiography (SEDR), Slot-Scan Digital Radiography, and Full-Field
Digital Radiography Systems for Chest Phantom Imaging. Medical Physics,
38, 23-33. http://dx.doi.org/10.1118/1.3519903 |
| [3] | Schaefer-Prokop,
C., Neitzel, U., Venema, H.W., Uffmann, M. and Prokop, M. (2008)
Digital Chest Radiography: An Update on Modern Technology, Dose
Containment and Control of Image Quality. European Journal of Radiology,
18, 1818-1830. http://dx.doi.org/10.1007/s00330-008-0948-3 |
| [4] | Donoho, D.L. (1995) De-Noising by Soft-Thresholding. IEEE Transactions on Information Theory, 41, 613-627. http://dx.doi.org/10.1109/18.382009 |
| [5] | Jansen,
M., Uytterhoeven, G. and Bultheel, A. (1999) Image De-Noising by
Integer Wavelet Transforms and Generalized Cross Validation. Medical
Physics, 26, 622-630. http://dx.doi.org/10.1118/1.598562 |
| [6] | Harpan, M.D. (1999) A Computer Simulation of Wavelet Noise Reduction in Computed Tomography. Medical Physics, 26, 1600-1606. http://dx.doi.org/10.1118/1.598654 |
| [7] | Okamoto,
T., Furui, S., Ichiji, H., Yoshino, S., Lu, J. and Yanagi, T. (2004)
Noise Reduction in Digital Radiography Using Wavelet Packet Based on
Noise Characteristics. Journal of Signal Processing, 8, 485-494. http://dx.doi.org/10.2299/jsp.8.485 |
| [8] | Tischenko,
O., Hoeschen, C. and Buhr, E. (2005) Reduction of Anatomical Noise in
Medical X-Ray Images. Radiation Protection Dosimetry, 114, 69-74. http://dx.doi.org/10.1093/rpd/nch518 |
| [9] | Ferrari,
R.J. and Winsor, R. (2005) Digital Radiographic Image Denoising via
Wavelet-Based Hidden Markov Model Estimation. Journal of Digital
Imaging, 18, 154-167. http://dx.doi.org/10.1007/s10278-004-1908-3 |
| [10] | Yasuda, N., Ishikawa, Y. and Kodera, Y. (2005) Improvement of Image Quality in Chest MDCT Using Nonlinear Wavelet Shrinkage with Trimmed-Thresholding. Japanese Journal of Radiological Technology, 61, 1599-1608. |
| [11] | Lee, Y., Tsai, D.Y. and Suzuki, T. (2008) Contrast Enhancement of Medical Images Using Sigmoid-Type Transfer Curves for Wavelet Coefficient Weighting Adjustment. Medical Imaging and Information Sciences, 25, 48-53. |
| [12] | Tsai, D.Y. and Lee, Y. (2003) A Method of Medical Image Enhancement Using Wavelet Coefficient Mapping Functions. Proceedings of IEEE International Conference on Neural Networks and Signal Processing, 2, 1091-1094. |
| [13] | Watanabe, H., Tsai, D.Y., Lee, Y., Matsuyama, E. and Kojima, K. (2011) An Integrated Method of Wavelet Coefficient Thresholding for Reducing Radiation Dose While Maintaining Diagnostic Image Quality. Medical Imaging and Information Sciences, 28, 51-56. |
| [14] | Chang,
S.G., Yu, B. and Vetterli, M. (2000) Adaptive Wavelet Thresholding for
Image Denoising and Compression. IEEE Transactions on Image Processing,
9, 1532-1546. http://dx.doi.org/10.1109/83.862633 |
| [15] | Donoho, D.L. and Johnstone, J.M. (1994) Ideal Spatial Adaptation via Wavelet Shrinkage. Biometrika, 81, 425-455. http://dx.doi.org/10.1093/biomet/81.3.425 |
| [16] | Donoho,
D.L. and John-stone, I.M. (1995) Adapting to Unknown Smoothness via
Wavelet Shrinkage. Journal of the American Statistical Association, 90,
1200-1224. http://dx.doi.org/10.1080/01621459.1995.10476626 |
| [17] | Zhang,
M. and Gunturk, B.K. (2008) Multiresolution Bilateral Filtering for
Image Denoising. IEEE Transactions on Image Processing, 17, 2324-2333. http://dx.doi.org/10.1109/TIP.2008.2006658 |
| [18] | Sendur,
L. and Selesnick, I.W. (2002) Bivariate Shrinkage Functions for
Wavelet-Based Denoising Exploiting Interscale Dependency. IEEE
Transactions on Signal Processing, 50, 2744-2756. http://dx.doi.org/10.1109/TSP.2002.804091 |
| [19] | Karthikeyan,
K. and Chandrasekar, C. (2011) Speckle Noise Reduction of Medical
Ultrasound Images Using Bayesshrink Wavelet Threshold. International
Journal of Computer Applications, 22, 8-14. http://dx.doi.org/10.5120/2614-3646 |
| [20] | Watanabe,
H., Tsai, D.Y., Lee, Y., Nakamura, T., Miyazaki, M., Kuramochi, Y. and
Kojima, K. (2009) Evaluation of Irreversible Compressed Images in
Computed Radiography Using Physical Image Quality Measures. Japanese
Journal of Radiological Technology, 65, 1618-1627. http://dx.doi.org/10.6009/jjrt.65.1618 |
| [21] | Samei,
E., Flynn, M.J. and Reimann, D.A. (1998) A Method for Measuring the
Presampled MTF of Digital Radiographic Systems Using an Edge Test
Device. Medical Physics, 25, 102-113. http://dx.doi.org/10.1118/1.598165 |
| [22] | Flynn,
M. and Samei, E. (1999) Experimental Comparison of Noise and Resolution
for 2k and 4k Storage Phosphor Radiography Systems. Medical Physics,
26, 1612-1623. http://dx.doi.org/10.1118/1.598656 |
| [23] | Neitzel,
U., Gunther-Kohfahl, S., Borasi, G. and Samei, E. (2004) Determination
of Detective Quantum Efficiency of a Digital X-Ray Detector: Comparison
of Three Evaluations Using a Common Image Data Set. Medical Physics, 31,
2205-2211. http://dx.doi.org/10.1118/1.1766421 |
| [24] | Samei,
E. and Flynn, M.J. (2002) An Experimental Comparison of Detector
Performance for Computed Radiography Systems. Medical Physics, 29,
447-459. http://dx.doi.org/10.1118/1.1449873 |
| [25] | Bankman, I.N. (2000) Handbook of Medical Imaging. Academic Press, San Diego, 24-26. eww150225lx |
| [26] | Lim, J.S. (1989) Two-Dimensional Signal and Image Processing. Prentice Hall, Englewood Cliffs, 548. |
评论
发表评论