Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=54096#.VO14EizQrzE
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=54096#.VO14EizQrzE
Author(s)
Affiliation(s)
1Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Japan.
2Digital Human Research Center, Agency for Industrial Science and Technology (AIST), Tokyo, Japan.
3Graduate School of Engineering, Hiroshima University, Hiroshima, Japan.
4Hello Tomorrow Japan Co. Ltd., Tokyo, Japan.
2Digital Human Research Center, Agency for Industrial Science and Technology (AIST), Tokyo, Japan.
3Graduate School of Engineering, Hiroshima University, Hiroshima, Japan.
4Hello Tomorrow Japan Co. Ltd., Tokyo, Japan.
ABSTRACT
Custom-made
esthetic finger prostheses, which are used for rehabilitation of
patients with missing or impaired fingers, have been fabricated
manually. However, such fabrication is time-consuming and requires
manual skill. Here we propose a computer-aided method for fabricating
finger pros-theses to save time and allow fabrications that do not
require considerable manual skill. In this method, the dimensions of a
patient’s healthy finger on the contralateral hand are first measured
using a caliper. Using these dimensions, a three-dimensional model is
constructed for fabricating a prosthesis for the patient’s impaired
finger. Using the 3D model, a mold is designed using 3D modeling tools
and a computer-aided design system. The resulting mold is then
fabricated using a 3D printer. A finger prosthesis is fabricated by
pouring silicone resin into the mold. A finger prosthesis for a
volunteer was experimentally fabricated according to the proposed
method. To evaluate the size and shape of the finger prosthesis, the
difference between the finger prosthesis and the original finger of the
volunteer was analyzed. Because the average difference between them was
0.25 mm, it was concluded that the proposed method could be used to
fabricate a finger prosthesis of adequate size and shape.
KEYWORDS
Cite this paper
References
Murayama,
T. , Oono, K. , Tada, M. , Eguchi, T. , Nagami, M. and Tamamoto, M.
(2015) Computer-Aided Design and Fabrication of Finger Prosthesis. Journal of Biomedical Science and Engineering, 8, 98-103. doi: 10.4236/jbise.2015.82010.
| [1] | Shanmuganathan,
N., Uma Maheswari, M., Anandkumar, V., Padmanabhan, T.V., Swarup, S.
and Jibran, A.H. (2011) Aesthetic Finger Prosthesis. The Journal of
Indian Prosthodontic Society, 11, 232-237. http://dx.doi.org/10.1007/s13191-011-0074-9 |
| [2] | Botolin,
L., Gazroda, S., Maver, T. and Ganter, G. (2007) Use of Rapid
Manufacturing Technology in Comprehensive Rehabilitation of a Patient
with Physical Body Disorders. http://digicen.si/clanki/nasi_clanki/ICIT_07_784_botolin.pdf |
| [3] | Fujita, S., Murayama, T., Tamamoto, M., Shimoe, S., Makihira, S., Sasahara, K., Kawahara, K., Satoda, T., Nikawa, H., Niitani, Y., Hara, K., Matsumoto, A., Takemoto, T. and Amano, H. (2009) Design and Fabrication of the Mold of Finger Prostheses by Using CAD and 3d-Printer. 93rd Regular Meeting of Hiroshima University Dental Society, Hiroshima, 24-25 October 2009, 120. (In Japanese) |
| [4] | De Crescenzio, F., Fantini, M., Ciocca, L., Persiani, F. and Scotti, R. (2011) Design and Manufacturing of Ear Prosthesis by Means of Rapid Prototyping Technology. Proceedings of the Institution of Mechanical Engineers, Part H, 225, 296-302. |
| [5] | Ciocca,
L., Mingucci, R., Gassino, G. and Scotti, R. (2007) CAD/CAM Ear Model
and Virtual Construction of the Mold. The Journal of Prosthetic
Dentistry, 98, 339-343. http://dx.doi.org/10.1016/S0022-3913(07)60116-4 |
| [6] | Jiao, T., Zhang, F., Huang, X. and Wang, C. (2004) Design and Fabrication of Auricular Prostheses by CAD/CAM System. The International Journal of Prosthodontics, 17, 460-463. |
| [7] | Karayazgan-Saracoglu,
B., Gunay, Y. and Atay, A. (2009) Fabrication of an Auricular
Prosthesis Using Computed Tomography and Rapid Prototyping Technique.
Journal of Craniofacial Surgery, 20, 1169-1172. http://dx.doi.org/10.1097/SCS.0b013e3181acdb95 |
| [8] | Liacouras,
P., Garnes, J., Roman, N., Petrich, A. and Grant, G.T. (2011) Designing
and Manufacturing an Auricular Prosthesis Using Computed Tomography,
3-Dimensional Photographic Imaging. The Journal of Prosthetic Dentistry,
105, 78-82. http://dx.doi.org/10.1016/S0022-3913(11)60002-4 |
| [9] | Turgut,
G., Sacak, B., Kiran, K. and Bas, L. (2009) Use of Rapid Prototyping in
Prosthetic Auricular Restoration. Journal of Craniofacial Surgery, 20,
321-325. http://dx.doi.org/10.1097/SCS.0b013e3181992266 |
| [10] | Subburaj,
K., Nair, C., Rajesh, S., Meshram, S.M. and Ravi, B. (2007) Rapid
Development of Auricular Prosthesis Using CAD and Rapid Prototyping
Technologies. International Journal of Oral and Maxillofacial Surgery,
36, 938-943. http://dx.doi.org/10.1016/j.ijom.2007.07.013 |
| [11] | Murayama,
T., Ogasawara, M., Eguchi, T., Morishita, Y. and Tamamoto, M. (2013)
Computer-Aided Technique for the Design and Manufacturing of Auricular
Prostheses. IFMBE Proceedings, 43, 593-596. http://dx.doi.org/10.1007/978-3-319-02913-9_151 |
| [12] | Kimura, K., Tada, M., Terabayashi, K. and Umeda, K. (2011) Subject-Specific Finger Model from Geometric Database. Proceedings of ISB2011, Brussels, 3-7 July 2011, 155. eww150225lx |
评论