跳至主要内容

Comparative Analysis of Internal and External-Hex Crown Connection Systems - A Finite Element Study

Read  full  paper  at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=8#.VNMsTizQrzE

ABSTRACT
The abutment connection with the crown is fundamental to the structural stability of the implant system and to the prevention of mechanical exertion that can compromise the success of the implant treatment. The aim of this study is to clarify the difference in the stress distribution patterns between implants with internal and external-hex connections with the crown using the Finite Element Method (FEM). Material and Methods: The internal and external-hex connections of the Neoss and 3i implant systems respectively, are considered. The geometrical properties of the implant systems are modeled using three-dimensional (3D) brick elements. Loading conditions include a masticatory force of 200, 500 and 1000N applied to the occlusal surface of the crown along with an abutment screw torque of 110, 320 and 550Nmm. The von Mises stress distributions in the crown are examined for all loading conditions. Assumptions made in the modeling include: 1. half of the implant system is modeled and symmetrical boundary conditions applied; 2. temperature sensitive elements are used to replicate the torque within the abutment screw. Results: The connection type strongly influences the resulting stress characteristics within the crown. The magnitude of stress produced by the internal-hex implant system is generally lower than that of the external-hex system. The internal-hex system held an advantage by including the use of an abutment between the abutment screw and the crown. Conclusions: The geometrical design of the external-hex system tends to induce stress concentrations in the crown at a distance of 2.89mm from the apex. At this location the torque applied to the abutment screw also affects the stresses, so that the compressive stresses on the right hand side of the crown are increased. The internal-hex system has reduced stress concentrations in the crown. However, because the torque is transferred through the abutment screw to the abutment contact, changing the torque has greater effect on this hex system than the masticatory force. Overall the masticatory force is more influential on the stress within the crown for the external-hex system and the torque is more influential on the internal-hex system.
 
Cite this paper
STADEN, R. , GUAN, H. , LOO, Y. and W. JOHNSON, N. (2008) Comparative Analysis of Internal and External-Hex Crown Connection Systems - A Finite Element Study. Journal of Biomedical Science and Engineering, 1, 10-14. doi: 10.4236/jbise.2008.11002.
 
References
[1]Y. Maeda, T. Satoh, M. Sogo, “In vitro differences of stress concentrations for internal and external hex implant–abutment connections: a short communication,” Journal of Oral Rehabilitation, vol. 33, pp. 75–78, 2006.
 
[2]B. R. Merz, S. Hunenbart, U. C. Belser, “Mechanics of the implant–abutment connection: an 8-degree taper compared to a butt joint connection,” International Journal of Oral and Maxillofacial Implants, vol. 15, pp. 519–526, 2000.
 
[3]A. Khraisat, R. Stegaroiu, S. Nomura, O. Miyakawa, “Fatigue resistance of two implant/abutment joint designs,” Journal of Prosthetic Dentistry, vol. 88, pp. 604–610, 2002.
 
[4]S. Capodiferro, G. Favia, M. Scivetti, G. De Frenza, R. Grassi, “Clinical management and microscopic characterisation of fatique-induced failure of a dental implant,” Case report. Head and Face Medicine, vol. 22, issue. 2, pp. 18, 2006.
 
[5]P. Gehrke, G. Dhom, J. Brunner, D. Wolf, M. Degidi, A. Piattelli, “Zirconium implant abutments: fracture strength and influence of cyclic loading on retaining-screw loosening,” Quintessence International, vol. 37, issue. 1, pp. 19-26, 2006.
 
[6]A. Khraisat, “Stability of implant-abutment interface with a hexagon-mediated butt joint: failure mode and bending resistance,” Clinical Implant Dentistry and Related Research, vol. 7, issue. 4, pp. 221-228, 2005.
 
[7]F. H. G. Butz, M. Okutan, J. R. Strub, “Survival rate, fracture strength and failure mode of ceramic implant abutments after chewing simulation,” Journal of Oral Rehabilitation, vol. 32, issue. 11, pp. 838-843, 2005.
 
[8]K. J. Anusavice, P. H. Dehoff, “Influence of metal thickness on stress distribution in metal-ceramic crowns,” Journal of Dental Research, vol. 65, issue. 9, pp. 1173-1178, 1986.
 
[9]K. J. Anusavice, “Stress distribution in metal-ceramic crowns with a facial porcelain margin,” Journal of Dental Research, vol. 66, issue. 9, pp. 1493-1498, 1987.
 
[10]K. J. Anusavice, “Influence of incisal length of ceramic and loading orientation on stress distribution in ceramic crowns,” Journal of Dental Research, vol. 67, issue. 11, pp. 1371-1375, 1988.
 
[11]H. Y. Suzuki, “Finite element stress analysis of ceramics crown on premolar. Relation between ceramics materials and abutment materials,” Nippon Hotetsu Shika Gakkai Zasshi, vol. 33, issue. 2, pp. 283-293, 1989.
 
[12]T. Hino, “A mechanical study on new ceramic crowns and bridges for clinical use,” Osaka Daigaku Shigaku Zasshi, vol. 35, issue. 1, pp. 240-267, 1990.
 
[13]B. Zhang, H. Wang, “Three-dimensional finite element analysis of all-ceramic crowns of the posterior teeth,” Hua Xi Yi Ke Da Xue Xue Bao, vol. 31, issue. 2, pp. 147-148, 2000.
 
[14]K. A. Proos, J. Ironside, G. P. Steven, “Finite element analysis studies of an all-ceramic crown on a first premolar,” International Journal of Prosthodontics, vol. 15, issue. 4, pp. 404-412, 2002.
 
[15]A. Imanishi, T. Ohyama, T. Nakamura, “3-D Finite element analysis of all-ceramic posterior crowns,” Journal of Oral Rehabilitation, vol. 30, issue. 8, pp. 818-822, 2003.
 
[16]Strand7 Pty Ltd, Strand7 Theoretical Manual, Sydney, Australia, 2004.
 
[17]Neoss Pty Ltd, Neoss Implant System Surgical Guidelines, United Kingdom, 2006.
 
[18]http://www.3i-online.com.htm (accessed 12th July 2006).
 
[19]R. C. van Staden, H. Guan, Y. C. Loo, N. W. Johnson, N. Meredith, “Stress Evaluation of Dental Implant Wall Thickness using Numerical Techniques,” Applied Osseointegration Research, (In Press), 2008.
 
[20]A. R. Curtis, A. J. Wright, G. J. Fleming, “The influence of simulated masticatory loading regimes on the bi-axial flexure strength and reliability of a Y-TZP dental ceramic,” Journal of Dentistry, vol. 34, issue. 5, pp. 317-325, 2005.
 
[21]D. H. DeTolla, S. Andreana, A. Patra, R. Buhite, B. Comella, “Role of the finite element model in dental implants,” Journal of Oral Implantology, vol. 26, issue. 2, pp. 77-81, 2000.
 
[22]J. P. Geng, K. B. Tan, G. R. Liu, ”Application of finite element analysis in implant dentistry: a review of the literature,” Journal of Prosthetic Dentistry, vol. 85, issue. 6, pp. 585-598, 2001.           eww150205lx

评论

此博客中的热门博文

Does Immigration Promote the Investment of the Monopolistic Firm?

In the present paper, we examine the effect of increasing uncertainty of immigrants’ growth on the optimal timing of investment of a firm that has a monopolistic power over the labor market. It is revealed that when the uncertainty of immigrants’ growth is more than a threshold level, increasing uncertainty of immigrants’ growth accelerates the optimal timing of firms’ investment and enhances the economic growth, even if the uncertainty of immigrants’ growth is formulated by the geometric Brownian motion, which is in sharp contrast to the standard result that an increase in the uncertainty postpones the optimal timing. With an increase in the immigrants over the past ten years, workforces in the host countries have been growing significantly to the extent that the immigrants represent 70% of the increase in the workforce in Europe, and 47% in the United States as OECD indicates. In the present paper, we attempted to investigate the effect of increased uncertainty caused by the growi...

Education Policy Implementation: A Mechanism for Enhancing Primary Education Development in Zanzibar

Education is one of the fundamental rights of individuals; therefore, the government of a country needs to develop and strengthen educational policy and quality as well as to ensure that everyone has equal access to basic education. The improvement of access and quality of education in the world is becoming as an essential factor in development, whereas the basic education (primary school), is acknowledged as a foundation of the higher educational development for every country. To fulfill this goal, governments introduce several policies and procedures; however, it requires some reforms and participation from the politician, policymakers, and other stakeholders to re-examine educational policy so that it can lead to multiplication and betterment of the reforms. Educational reforms actually focus on accountability. A positive educational development and reform is very challenging and needs more effort and strategy on how to use and utilize the resources effectively as such it can achie...