Optimum Combination of Femoral Head Size, Femoral Head Material, and Acetabular Cup Liner’s Highly-Cross-Linked Polyethylene Brand for Hip Implant
Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=53277#.VLxqgcnQrzE
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=53277#.VLxqgcnQrzE
ABSTRACT
Clinical
two-dimensional linear wear rate data for acetabular cup liners
fabricated using approved brands of highly cross-linked
ultra-high-molecular-weight polyethylene, as reported in 39 articles in
the literature, were analyzed using a statistical technique called
response surface methodology. The output was a series comprising16
acceptable combinations of femoral head diameter (HD), femoral head
material (HM), and HXLPE brand (PB), each of which would yield the
optimum wear rate (herein taken to be a wear rate of practically zero).
An example of such a combination is 28- mm-diameter Oxinium® femoral head articulated against an acetabular cup liner fabricated from ReflectionTM
HXLPE. The findings in this work may guide an orthopaedic surgeon’s
selection of the combination of HD, HM, and PB to use in a primary total
hip joint replacement.
KEYWORDS
Cite this paper
References
Lewis,
G. and Werdofa, D. (2015) Optimum Combination of Femoral Head Size,
Femoral Head Material, and Acetabular Cup Liner’s Highly-Cross-Linked
Polyethylene Brand for Hip Implant. Journal of Biomedical Science and Engineering, 8, 31-39. doi: 10.4236/jbise.2015.81003.
[1] | Kurtz,
S.M., Gawel, H.A. and Patel, J.D. (2011) History and Systematic of Wear
and Osteolysis Outcomes for First-Generation Highly Crosslinked
Polyethylene. Clinical Orthopaedics and Related Research, 469,
2262-2277. http://dx.doi.org/10.1007/s11999-011-1872-4 |
[2] | Martell,
J.M., Verner, J.J. and Incavo, S.J. (2003) Clinical Performance of a
Highly Cross-Linked Polyethylene at Two Years in Total Hip Arthroplasty:
A Randomized Prospective Trial. The Journal of Arthroplasty, 18, 55-59. http://dx.doi.org/10.1016/S0883-5403(03)00341-3 |
[3] | Hopper,
R.H., Young, A.M., Orishimo, K.F. and McAuley, J.P. (2003) Correlation
between Early and Late Wear Rates in Total Hip Arthroplasty with
Application to the Performance of Marathon Cross-Linked Polyethylene
Liners. The Journal of Arthroplasty, 18, 60-67. http://dx.doi.org/10.1016/S0883-5403(03)00294-8 |
[4] | Krushell,
R.J., Fingeroth, R.J. and Cushing, M.C. (2005) Early Femoral Head
Penetration of a Highly Cross-Linked Polyethylene Liner vs a
Conventional Polyethylene Liner. The Journal of Arthroplasty, 20, 73-76. http://dx.doi.org/10.1016/j.arth.2005.05.008 |
[5] | D’Antonio,
J.A., Manley, M.T., Capello, W.N., Bierbaum, B.E., Ramakrishnan, R.,
Naughton, M. and Sulton, K. (2005) Five-Year Experience with Crossfire
Highly Cross-Linked Polyethylene. Clinical Orthopaedics and Related
Research, 441, 143-150. http://dx.doi.org/10.1097/00003086-200512000-00024 |
[6] | Manning,
D.W., Chiang, P.P., Martell, J.M., Galante, J.O. and Harris, W.H.
(2005) In Vivo Comparative Wear Study of Traditional and Highly
Cross-Linked Polyethylene in Total Hip Arthroplasty. The Journal of
Arthroplasty, 20, 880-886. http://dx.doi.org/10.1016/j.arth.2005.03.033 |
[7] | Dorr, L.D., Wan, Z., Shahrdar, C., Sirianni, L., Boutary, M. and Yun, A. (2005) Clinical Performance and a Durasul Highly Cross-Linked Polyethylene Acetabular Liner for Total Hip Arthroplasty at Five Years. Journal of Bone and Joint Surgery, 87-A, 1816-1821. |
[8] | Engh
Jr., C.A., Stepniewski, A.S., Ginn, S.D., Beykirch, S.E.,
Sychterz-Terefenko, C.J., Hopper, R.H. and Engh, C.A. (2006) A
Randomized Prospective Evaluation of Outcomes after Total Hip
Arthroplasty Sing Cross-Linked Marathon and Non-Cross-Linked Enduron
Polyethylene Liners. The Journal of Arthroplasty, 21, 17-25. http://dx.doi.org/10.1016/j.arth.2006.05.002 |
[9] | Bradgon, C.R., Barrett, S., Martell, J.M., Greene, M.E., Malchau, H. and Harris, W.H. (2006) Steady-State Penetration Rates of Electron Beam-Irradiated, Highly Cross-Linked Polyethylene at an Average 45-Month Follow-Up. The Journal of Arthroplasty, 21, 935-943. |
[10] | Oonishi,
H., Kim, S.C., Takao, Y., Kyomoto, M., Iwamoto, M. and Ueno, M. (2006)
Wear of Highly Cross-Linked Polyethylene Acetabular Cup in Japan. The
Journal of Arthroplasty, 21, 944-949. http://dx.doi.org/10.1016/j.arth.2006.03.009 |
[11] | Bragdon, C.R., Kwan, Y.M., Geller, J.A., Greene, M.E., Freiberg, A.A., Harris, W.H. and Malchau, H. (2007) Minimum 6-Year Follow-Up of Highly Cross-Linked Polyethylene in THA. Clinical Orthopaedics and Related Research, 465, 122-127. |
[12] | Leung,
S.B., Egawa, H., Stepnieswski, A., Beykirch, S., Engh, C.A. and Engh,
C.A. (2007) Incidence and Volume of Pelvic Osteolysis at Early Follow-Up
with Highly Cross-Linked and Noncross-Linked Polyethylene. Journal of
Arthroplasty, 22, 134-139. http://dx.doi.org/10.1016/j.arth.2007.04.006 |
[13] | Rohrl,
S.M., Li, M.G., Nilsson, K.G. and Nivbrant, B. (2007) Very Low Wear of
Non-Remelted Highly Cross-Linked Polyethylene Cups: An RSA Study Lasting
up to 6 Years. Acta Orthopaedica, 78, 739-745. http://dx.doi.org/10.1080/17453670710014509 |
[14] | Triclot,
P., Grosjean, G., Masri, F.E., Courpied, J.P. and Hamadouche, M. (2007)
A Comparison of Penetration Rate of Two Polyethylene Acetabular Liners
of Different Levels of Cross-Linked: A Prospective Randomized Trial.
Journal of Bone and Joint Surgery-British Volume, 89-B, 1439-1445. http://dx.doi.org/10.1302/0301-620X.89B11.19543 |
[15] | Olyslaegers,
C., Defoort, K., Simon, J.P. and Vandenberghe, L. (2008) Wear in
Conventional and Highly Cross-Linked Polyethylene Cups: A 5-Year
Follow-Up Study. Journal of Arthroplasty, 23, 489-494. http://dx.doi.org/10.1016/j.arth.2007.02.013 |
[16] | Glyn-Jones,
S., Smith, P.M., Gill, H.S. and Murray, D.W. (2008) The Creep and Wear
of Highly Cross-Linked Polyethylene: A Three-Year Randomized, Controlled
Trial Using Radiostereometric Analysis. Journal of Bone and Joint
Surgery-British Volume, 90-B, 556-561. http://dx.doi.org/10.1302/0301-620X.90B5.20545 |
[17] | Bitsch,
R.G., Loidolt, T., Heisel, C., Ball, S. and Schmalzried, T.P. (2008)
Reduction of Osteolysis with Use of Marathon Cross-Linked Polyethylene: A
Concise Follow-Up, at a Minimum of Five Years, of a Previous Report.
Journal of Bone and Joint Surgery (American), 90, 1487-1491. http://dx.doi.org/10.2106/JBJS.F.00991 |
[18] | Garvin,
K.L., Hartman, C.W., Mangla, J., Murdoch, N. and Martell, J.M. (2009)
Wear Analysis in THA Utilizing Zirconium and Cross-Linked Polyethylene.
Clinical Orthopaedics and Related Research, 467, 141-145. http://dx.doi.org/10.1007/s11999-008-0544-5 |
[19] | Rajadhyaksha,
A.M., Brotea, C., Cheung, Y., Kuhn, C., Ramakrishnan, R. and Zelicof,
S.B. (2009) Five-Year Comparative Study of Highly Cross-Linked
(Crossfire) and Traditional Polyethylene. Journal of Arthroplasty, 24,
161-167. http://dx.doi.org/10.1016/j.arth.2007.09.015 |
[20] | Calvert,
G.T., Devane, P.A., Fielden, J., Adams, K. and Horne, J.G. (2009) A
Double-Blind, Prospective, Randomized Controlled Trial Comparing Highly
Cross-Linked and Conventional Polyethylene in Primary Total Hip
Arthroplasty. Journal of Arthroplasty, 24, 505-510. http://dx.doi.org/10.1016/j.arth.2008.02.011 |
[21] | Kim,
Y.H., Kim, J.S., Choi, Y.W. and Kwon, O.R. (2009) Intermediate Results
of Simultaneous Alumina-on-Alumina Bearing and Alumina-on-Highly
Cross-Linked Polyethylene Bearing Total Hip Arthroplasties. Journal of
Arthroplasty, 24, 885-891. http://dx.doi.org/10.1016/j.arth.2008.05.009 |
[22] | Geerdink,
C.H., Grimm, B., Vencken, W., Heyligers, I.C. and Tonino, A.J. (2009)
Cross-Linked Compared with Historical Polyethylene in THA: An 8-Year
Clinical Study. Clinical Orthopaedics and Related Research, 467,
979-984. http://dx.doi.org/10.1007/s11999-008-0628-2 |
[23] | Yun,
H.H., Jajodia, N.K., Myung, J.S., Oh, J.K., Park, S.W. and Shon, W.Y.
(2009) Use of Slide Presentation Software as a Tool to Measure Hip
Arthroplasty Wear. Journal of Arthroplasty, 24, 1210-1215. http://dx.doi.org/10.1016/j.arth.2009.06.012 |
[24] | Ise,
K., Kawanabe, K., Tamura, J., Akiyama, H., Goto, K. and Nakamura, T.
(2009) Clinical Results of the Wear Performance of Cross-Linked
Polyethylene in Total Hip Arthroplasty, Prospective Randomized Trial.
Journal of Arthroplasty, 24, 1216-1220. http://dx.doi.org/10.1016/j.arth.2009.05.020 |
[25] | Kawate,
K., Ohmura, T., Kawahara, I., Tamai, K., Ueha, T. and Takemura, K.
(2009) Differences in Highly Cross- Linked Polyethylene Wear between
Zirconia and Cobalt-Chromium Femoral Heads in Japanese Patients. Journal
of Arthroplasty, 24, 1221-1224. http://dx.doi.org/10.1016/j.arth.2009.05.023 |
[26] | Beksac,
B., Salas, A., Della Valle, A.G. and Salvati, E.A. (2009) Wear in
Reduced in THA Performed with Highly Cross-Linked Polyethylene. Clinical
Orthopaedics and Related Research, 467, 1765-1772. http://dx.doi.org/10.1007/s11999-008-0661-1 |
[27] | Shia,
D.S., Clohisy, J.C., Schinsky, M.F., Martell, J.M. and Maloney, W.J.
(2009) THA with Highly Cross-Linked Polyethylene in Patients 50 Years or
Younger. Clinical Orthopaedics and Related Research, 467, 2059-2065. http://dx.doi.org/10.1007/s11999-008-0697-2 |
[28] | Lachiewicz,
P.F., Heckman, D.S., Soileau, E.S., Mangla, J. and Martell, J.M. (2009)
Femoral Head Size and Wear of Highly Cross-Linked Polyethylene at 5 to 8
Years. Clinical Orthopaedics and Related Research, 467, 3290-3296. http://dx.doi.org/10.1007/s11999-009-1038-9 |
[29] | Campbell,
D., Mercer, G., Nilson, K.G., Wells, V., Field, J.R. and Callary, S.A.
(2010) Wear of a Highly Cross-Linked Polyethylene Liner: A Preliminary
RSA Study. European Journal of Orthopaedic Surgery & Traumatology,
20, 23-27. http://dx.doi.org/10.1007/s00590-009-0486-y |
[30] | Fukui,
K., Kaneuji, A., Sugimori, T., Ichiseki, T., Kitamura, K. and
Matsumoto, T. (2011) Wear Comparison between a Highly Cross-Linked
Polyethylene and Conventional Polyethylene against a Zirconia Femoral
Head: Minimum 5-Year Follow-Up. Journal of Arthroplasty, 26, 45-49. http://dx.doi.org/10.1016/j.arth.2009.11.005 |
[31] | Whittaker,
J.P., Charron, K.D., McCalden, R.W., MacDonald, S.J. and Bourne, R.B.
(2010) Comparison of Steady State Femoral Head Penetration Rates between
Two Highly Cross-Linked Polyethylenes in Total Hip Arthroplasty.
Journal of Arthroplasty, 25, 680-686. http://dx.doi.org/10.1016/j.arth.2009.05.006 |
[32] | Hammerberg,
E.M., Wan, Z., Dastane, M. and Dorr, L.D. (2010) Wear and Range of
Motion of Different Femoral Head Sizes. Journal of Arthroplasty, 25,
839-843. http://dx.doi.org/10.1016/j.arth.2009.07.007 |
[33] | Nakahara,
I., Nakamura, N., Nishii, T., Miki, H., Sakai, T. and Sugano, N. (2010)
Minimum Five-Year Follow-Up Wear Measurement of Longevity Highly
Cross-Linked Polyethylene Cup against Cobalt-Chromium or Zirconia Heads.
Journal of Arthroplasty, 25, 1182-1187. http://dx.doi.org/10.1016/j.arth.2009.09.006 |
[34] | Campbell,
D., Field, J.R. and Callary, S.A. (2010) Second-Generation Highly
Cross-Linked X3 Polyethylene Wear: A Preliminary Radiostereometric
Analysis Study. Clinical Orthopaedics and Related Research, 468,
2704-2709. http://dx.doi.org/10.1007/s11999-010-1259-y |
[35] | Mutimer,
J., Devane, P.A., Adams, K. and Horne, J.G. (2010) Highly Crosslinked
Polyethylene Reduces Wear in Total Hip Arthroplasty at 5 Years. Clinical
Orthopaedics and Related Research, 468, 3228-3233. http://dx.doi.org/10.1007/s11999-010-1379-4 |
[36] | Meftah,
M., Ebrahimpour, B., He, C., Rabawat, A.S. and Ranawat, C.S. (2011)
Short-Term Analysis and Clinical Performance of Large Ceramic Heads on
Highly Cross-Linked Polyethylene in Young and Active Patients. Seminars
in Arthroplasty, 22, 225-228. http://dx.doi.org/10.1053/j.sart.2011.09.002 |
[37] | Mall,
N.A., Nunley, R.M., Zhu, J.J., Maloney, W.J., Barrack, R.L. and
Clohisy, J.C. (2011) The Incidence of Acetabular Osteolysis in Young
Patients with Conventional versus Highly Crosslinked Polyethylene.
Clinical Orthopaedics and Related Research, 469, 372-381. http://dx.doi.org/10.1007/s11999-010-1518-y |
[38] | Capello,
W.N., D’Antonio, J.A., Ramakrishnan, R. and Naughton, M. (2011)
Continued Improved Wear with an Annealed Highly Cross-Linked
Polyethylene. Clinical Orthopaedics and Related Research, 469, 825-830. http://dx.doi.org/10.1007/s11999-010-1556-5 |
[39] | Rohrl,
S.M., Nivbrant, B. and Nilsson, K.G. (2012) No Adverse Effects of
Submelt-Annealed Highly Crosslinked Polyethylene in Cemented Cups. An
RSA Study of 8 Patients 10 Years after Surgery. Acta Orthopaedica, 83,
148-152. http://dx.doi.org/10.3109/17453674.2011.652889 |
[40] | Ranawat,
A.S., Tsallis, P., Meftah, M., Koob, T.W., Rodriguez, J.A. and Ranawat,
C.S. (2012) Minimum 5-Year Wear Analysis of First-Generation Highly
Cross-Linked Polyethylene in Patients 65 Years and Younger. Journal of
Arthroplasty, 27, 354-357. http://dx.doi.org/10.1016/j.arth.2011.07.003 |
[41] | Johanson,
P.E., Digas, G., Herberts, P., Thanner, J. and Karrholm, J. (2012)
Highly Crosslinked Polyethylene Does Not Reduce Aseptic Loosening in
Cemented THA 10-Year Findings of a Randomized Study. Clinical
Orthopaedics and Related Research, 470, 3083-3093. http://dx.doi.org/10.1007/s11999-012-2400-x |
[42] | Bradgon,
C.R., Doerner, M., Martell, J., Jarrett, B., Palm, H. and Malchau, H.,
Multicenter Study Group (2013) The 2012 John Charnley Award: Clinical
Multicenter Studies of the Wear Performance of Highly Crosslinked
Remelted Polyethylene in THA. Clinical Orthopaedics and Related
Research, 471, 393-402. http://dx.doi.org/10.1007/s11999-012-2604-0 |
[43] | Babovic,
N. and Trousdale, R.T. (2013) Total Hip Arthroplasty Using Highly
Cross-Linked Polyethylene in Patients Younger than 50 Years with Minimum
10-Year Follow-Up. Journal of Arthroplasty, 28, 815-817. http://dx.doi.org/10.1016/j.arth.2012.12.005 |
[44] | Callary,
S.A., Campbell, D.G., Mercer, G., Nilsson, K.G. and Field, J.R. (2013)
Wear of a 5 Megarad Cross-Linked Polyethylene Liner: A 6-Year RSA Study.
Clinical Orthopaedics and Related Research, 471, 2238-2244. http://dx.doi.org/10.1007/s11999-013-2789-x |
[45] | Kim,
Y.H., Park, J.W., Patel, C. and Kim, D.Y. (2013) Polyethylene Wear and
Osteolysis after Cementless Total Hip Arthroplasty with
Alumina-on-Highly Cross-Linked Polyethylene Bearings in Patients Younger
than Thirty Years of Age. Journal of Bone and Joint Surgery (American),
95, 1088-1093. http://dx.doi.org/10.2106/JBJS.L.01211 |
[46] | Fukui,
K., Kaneuji, A., Sugimori, T., Ichiseki, T. and Matsumoto, T. (2013)
Wear Comparison between Conventional and Highly Cross-Linked
Polyethylene against a Zirconia Head: A Concise Follow-Up, at an Average
10 Years, of a Previous Report. Journal of Arthroplasty, 28, 1654-1658.
http://dx.doi.org/10.1016/j.arth.2012.12.020 |
[47] | Callary,
S.A., Field, F.R. and Campbell, D.G. (2013) Long Wear of a
Second-Generation Highly Crosslinked Polyethylene Liner: A 5-Year
Radiostereometric Analysis Study. Clinical Orthopaedics and Related
Research, 471, 3596- 3600. http://dx.doi.org/10.1007/s11999-013-3188-z |
[48] | Myers, R.H. (2008) RSM: Process and Product Optimization Using Designed Experiments. John Wiley & Sons, Inc, New York. |
[49] | Haraguchi,
K., Sugano, N., Nishii, T., Miki, H., Oka, K. and Yoshikawa, H. (2001)
Phase Transformation of a Zirconia Ceramic Head after Total Hip
Arthroplasty. Journal of Bone and Joint Surgery, 83-B, 996-1000. http://dx.doi.org/10.1302/0301-620X.83B7.12122 |
[50] | Stroh,
D.A., Issa, K., Johnson, A.J., Delanois, R.E. and Mont, M.A. (2013)
Reduced Dislocation Rates and Excellent Functional Outcomes with
Large-Diameter Femoral Heads. Journal of Arthroplasty, 28, 1415-1420. http://dx.doi.org/10.1016/j.arth.2012.11.017 |
[51] | Allen,
C.L., Hooper, G.J. and Frampton, C.M.A. (2014) Do Larger Femoral Heads
Improve the Functional Outcome in Total Hip Arthroplasty? Journal of
Arthroplasty, 29, 401-404. http://dx.doi.org/10.1016/j.arth.2013.06.017 |
[52] | Martell, J.M., Berkson, E., Berger, R. and Jacobs, J. (2003) Comparison of Two- and Three-Dimensional Computerized Polyethylene Wear Analysis after Total Hip Arthroplasty. Journal of Bone and Joint Surgery, 85-A, 1111-1117. |
[53] | Aggarwal,
M.L. and Bansal, A. (1998) Robust Response Surface Designs for
Qualitative and Quantitative Factors. Communications in
Statistics-Theory and Methods, 27, 89-106. http://dx.doi.org/10.1080/03610929808832652 eww150119lx |
评论
发表评论