Methods to Minimize Optical Noise That Degrade Fluorescence Efficiency of Optical Probe for Near-Infrared Tracking in Surgical Environment
Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=53338#.VL3H5yzQrzE
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=53338#.VL3H5yzQrzE
Author(s)
Affiliation(s)
1Medical Photonics Research Center, Korea Photonics Technology Institute, Gwangju, South Korea.
2Interdisciplinary Program of Biomedical Engineering, Chonnam National University, Gwangju, South Korea.
3Department of Nuclear Medicine, National Cancer Center, Goyang, South Korea.
2Interdisciplinary Program of Biomedical Engineering, Chonnam National University, Gwangju, South Korea.
3Department of Nuclear Medicine, National Cancer Center, Goyang, South Korea.
ABSTRACT
In the medical field, there are growing interests in applied research such as in vivo
fluorescence monitoring because of excellent body transmission
characteristic of the near-infrared light. However, optical noise by
excitation light and illumination equipment for medical applications
such as interior light, surgical light decrease efficiency of the
fluorescent signal when observers such as surgeons confirm fluorescence
signals in medical field. To solve these problems in medical field, we
have analyzed external noise factors by effect on image realization,
quantification of optical noise generation by external factors, and have
suggested methods of minimize the optical noise in this paper. In case
of fluorescence imaging in the operating room, it has been confirmed
that fluorescent excitation light, interior light and surgical light are
factors to generate optical noise. To acquire near-infrared
fluorescence images and to compare fluorescence contrast under
conditions of darkroom, interior light and surgical light, light
emitting diodes (LEDs) sources that have peak wavelength at 740, 760 and
780 nm respectively were used as excitation light sources. In addition,
short-pass filter which has transmission edge at 775 nm has been
applied to minimize the optical noise in each external noise factor. By
comparing contrast of each image before and after use of the short-pass
filter, we confirmed that optical noise reduced 49%, 56% and 66% in
external noise factors respectively.
Cite this paper
References
Park,
H. , Shin, I. , Park, J. , Eom, J. , Kim, S. and Lee, B. (2015) Methods
to Minimize Optical Noise That Degrade Fluorescence Efficiency of
Optical Probe for Near-Infrared Tracking in Surgical Environment. Journal of Biomedical Science and Engineering, 8, 56-65. doi: 10.4236/jbise.2015.81006.
| [1] | Lee, B.-I., Kim, H.S., Jeong, H.J., Lee, H.J., Moon, S.M., Kwon, S.Y., Choi, E.S., Jeong, S.Y., Bom, H.S. and Min, J.J. (2009) Development of Optical Molecular Imaging System for the Acquisition of Bioluminescence Signals from Small Animals. Nuclear Medicine and Molecular Imaging, 43, 344-351. |
| [2] | Leblond,
F., Davis, S.C., Valdés, P.A. and Pogue, B.W. (2010) Pre-Clinical
Whole-Body Fluorescence Imaging: Review of Instruments, Methods and
Applications. Journal of Photochemistry and Photobiology B: Biology, 98,
77-94. http://dx.doi.org/10.1016/j.jphotobiol.2009.11.007 |
| [3] | Kim, D.E. (2006) Molecular Optical Imaging in Neuroscience. Journal of the Korean Neurological Association, 24, 101-105. |
| [4] | Alander,
J.T., Kaartinen, I., Laakso, A., Patila, T., Spillmann, T., Tuchin,
V.V., Venermo, M. and Valisuo, P. (2012) A Review of Indocyanine Green
Fluorescent Imaging in Surgery. Journal of Biomedical Imaging, 2012,
1-26. http://dx.doi.org/10.1155/2012/940585 |
| [5] | Ntziachristos, V. (2006) Fluorescence Molecular Imaging. Annual Review of Biomedical Engineering, 8, 1-33. http://dx.doi.org/10.1146/annurev.bioeng.8.061505.095831 |
| [6] | Shin,
I.H., Kim, S.K., Eom, J.B., Park, J.S., Park, H.J., Park, I.K. and Lee,
B.-I. (2013) Novel Imaging System for Positioning of the Indocyanine
Green (ICG) Target; Visible Projection of the Near-Infrared Fluorescence
Image. Journal of Biomedical Science and Engineering, 6, 896-900. http://dx.doi.org/10.4236/jbise.2013.69109 |
| [7] | Shin,
I.H., Eom, J.B., Park, J.S., Park, H.J. and Lee, B.-I. (2014) Optical
Probe for Near-Infrared (NIR) Fluorescence Signal Detection with High
Optical Performance and Thermal Stability. Journal of Biomedical Science
and Engineering, 7, 792-798. http://dx.doi.org/10.4236/jbise.2014.710078 |
| [8] | Gioux, S., Choi, H.S. and Frangioni, J.V. (2010) Image-Guided Surgery Using Invisible Near-Infrared Light: Fundamentals of Clinical Translaton. Molecular Imaging, 9, 237-255. |
| [9] | Frangioni, J.V. (2003) In Vivo Near-Infrared Fluorescence Imaging. Current Opinion in Chemical Biology, 7, 626-634. http://dx.doi.org/10.1016/j.cbpa.2003.08.007 |
| [10] | Boddington,
S.E., Henning, T.D., Jha, P., Schlieve, C.R., Mandrussow, L., DeNardo,
D., Bernstein, H.S., Ritner, C., Golovko, D., Lu, Y., Zhao S. and
Daldrup-Link, H.E. (2010) Labeling Human Embryonic Stem Cell-Derived
Cardiomyocytes with Indocyanine Green for Noninvasive Tracking with
Optical Imaging: An FDA-Compatible Alternative to Firefly Luciferase.
Cell Transplantation, 19, 55-65. http://dx.doi.org/10.3727/096368909X478579 |
| [11] | Kongmire,
M.R., Gunn, A.J., Morgan, N.Y., Smith, P.D., Pohida, T.J., Koyama, Y.,
Kobayashi, H. and Choyke, P.L. (2007) Real-Time Fluorescence-Enhanced
Imaging as an Aid to Surgery in Ovarian Cancer. IEEE Journal of Selected
Topics in Quantum Electronics, 13, 1602-1609. http://dx.doi.org/10.1109/JSTQE.2007.910998 |
| [12] | Keereweer,
S., Kerrebijn, J.D.F., van Driel, P.B.A.A., Xie, B., Kaijzel, E.L.,
Snoeks, T.J.A., Que, I., Hutteman, M., van der Vorst, J.R., Mieog, J.,
Sven D., Vahrmeijer, A.L., van de Velde, C.J.H., Baatengurg de Jong,
R.J. and Lowik, C.W.G.M. (2011) Optical Image-Guided Surgery—Where Do We
Stand? Molecular Imaging and Biology, 13, 199-207. http://dx.doi.org/10.1007/s11307-010-0373-2 |
| [13] | Frangioni, J.V. (2008) New Technologies for Human Cancer Imaging. Journal of Clinical Oncology, 26, 4012-4021. http://dx.doi.org/10.1200/JCO.2007.14.3065 |
| [14] | Marshall, M.V., Rasmussen, J.C., Tan, I.C., Aldrich, M.B., Adams, K.E., Wang, X., Fife, C.E., Maus, A., Smith, L.A. and Sevick-Muraca, E.M. (2010) Near-Infrared Fluorescence Imaging in Humans with Indocyanine Green: A Review and Update. Open Surgical Oncology Journal, 2, 12-25. |
| [15] | Waseda,
K., Ako, J., Hasegawa, T., Shimada, Y., Ikeno, F., Ishikawa, T.,
Demura, Y., Hatada, K., Yock, P.G., Honda, Y., Fitzgerald, P.J. and
Takahashi, M. (2009) Intraoperative Fluorescence Imaging System for
On-Site Assessment of Off-Pump Coronary Artery Bypass Graft. The Journal
of the American College of Cardiology Cardiovascular Imaging, 2,
604-612. http://dx.doi.org/10.1016/j.jcmg.2008.12.028 |
| [16] | Choi,
M.H., Choi, K.S., Ryu, S-W., Lee, J.W. and Choi, C.H. (2011) Dynamic
Fluorescence Imaging for Multiparametric Measurement of Tumor
Vasculature. Journal of Biomedical Optics, 16, Article ID: 046008. http://dx.doi.org/10.1117/1.3562956 |
| [17] | Sano,
K., Mitsunaga, M., Nakajima, T., Choyke, P.L. and Kobayashi, H. (2012)
In Vivo Breast Cancer Characterization Imaging Using Two Monoclonal
Antibodies Activatably Labeled with Near Infrared Fluorophores. Breast
Cancer Research, 14, R61. http://dx.doi.org/10.1186/bcr3167 |
| [18] | Yokoyama,
J., Ito, S., Ohba, S., Fujimaki, M. and Ikeda, K. (2011) A Novel
Approach to Translymphatic Chemotherapy Targeting Sentinel Lymph Nodes
of Patients with Oral Cancer Using Intra-Arterial
Chemotherapy—Preliminary Study. Head & Neck Oncology, 3, 1-6. http://dx.doi.org/10.1186/1758-3284-3-42 |
| [19] | Tanaka,
E., Choi, H.S., Fujii, H., Bawendi, M.G. and Frangioni, J.V. (2006)
Image-Guided Oncologic Surgery Using Invisible Light: Completed
Pre-Clinical Development for Sentinel Lymph Node Mapping. Annals of
Surgical Oncology, 13, 1671-1681. http://dx.doi.org/10.1245/s10434-006-9194-6 |
| [20] | Matsui,
A., Lee, B.T., Winer, J.H., Kianzad, V. and Frangioni, J.V. (2009)
Image-Guided Perforator Flap Design Using Invisible Near-Infrared Light
and Validation with X-Ray angiography. Annals of Plastic Surgery, 63,
327-330. http://dx.doi.org/10.1097/SAP.0b013e318193493d |
| [21] | Morita,
Y., Sakaguchi, T., Unno, N., Shibasaki, Y., Suzuki, A., Fukumoto, K.,
Inaba, K., Baba, S., Takehara, Y., Suzuki, S. and Konno, H. (2013)
Detection of Hepatocellular Carcinomas with Near-Infrared Fluorescence
Imaging Using Indocyanine Green: Its Usefulness and Limitation.
International Journal of Clinical Oncology, 18, 232-241. http://dx.doi.org/10.1007/s10147-011-0367-3 |
| [22] | Abe,
H., Mori, T., Umeda, T., Tanaka, M., Kawai, Y., Shimizu, T., Cho, H.,
Kubota, Y., Kurumi, Y. and Tani, T. (2011) Indocyanine Green
Fluorescence Imaging System for Sentinel Lymph Node Biopsies in Early
Breast Cancer Patients. Surgery Today, 41, 197-202. http://dx.doi.org/10.1007/s00595-009-4254-8 |
| [23] | Yamamoto, M., Orihashi, K. and Sato, T. (2013) Intraoperative Indocyanine Green Imaging Technique in Cardiovascular Surgery. InTech, 81-97. eww150120lx |
评论
发表评论