Read full paper at:
ABSTRACT
Background:
Computed Tomography Angiography (CTA) is a new and promising type of
imaging to evaluate cardiac structure and function. Although it does
require injection of contrast material and some radiation exposure, it
is much less invasive than conventional catheter based on angiography.
It has been already shown to correlate well with echocardiography
images, but normative values have yet to be established. Objectives: To
publish the first known data on CTA measurements for all four chambers
of the heart. Methods: We conducted a retrospective chart review study
of around 3000 patients over a three-year period (2006-2008) from a
private cardiology practice in Phoenix, Arizona. Patients were screened
for any preexisting conditions that might contribute to abnormal cardiac
structures. A “normal” population of 226 patients’ CTA’s was reviewed
and 29 different measurements were taken cardiac anatomy. Patients were
then categorized based on sex and BMI and the cardiac measurements were
compared. Results: The values obtained were similar to already
established normal measurement values from echocardiography. There was
good correlation between body mass index (BMI) and the sexes.
Conclusion: This study serves to establish normative data for cardiac
CTA while also proves to show good correlation with already established
normative values for echocardiography and justifies these CTA
measurements as an alternative means of cardiac evaluation. Further
study regarding the variations between data for specific measurements
will be addressed in future studies.
Cite this paper
References
Whittington,
W. , Loli, A. , Gerkin, R. and Desser, K. (2014) Four Chamber Normative
Data for Computed Tomography Angiography in the Axial Plane. World Journal of Cardiovascular Surgery, 4, 69-76. doi: 10.4236/wjcs.2014.44011.
| [1] | Lloyd-Jones, D., et al. (2009) Heart Disease and Stroke Statistics—2009 Update: Report from the American Heart Association Statistics Committee and Stroke Subcommittee. Circulation, 119, e21-e161. |
| [2] | Henneman, M., et al. (2006) Global and Regional Left Ventricular Function: A Comparison Between Gated SPECT, 2D Echocardiography and Multi-Slice Computed Tomography, European Journal of Nuclear Medicine and Molecular Imaging, 33, 1452-1460. |
| [3] | Prat-Gonzalez, S., Sanz, J., Garcia, M. and Cardiac, C.T. (2008) Indications and Limitations. Journal of Nuclear Medicine Technology, 36, 18-24. http://dx.doi.org/10.2967/jnmt.107.042424 |
| [4] | Ryding, A. (2008) Essential Echocardiograpy. Elsevier Limited, Amsterdam. |
| [5] | Erbel, R., Schweizer, P., Krebs, W., Meyer, J. and Effert, S. (1984) Sensitivity and Specificity of Two Dimensional Echocardiography in Detection of Impaired Left Ventricular Function. European Heart Journal, 5, 477-489. |
| [6] | Sibley, C. and Lima, J. (2008) Assessment of Ventricular Structure and Function with Multidetector CT and MRI. Current Cardiology Reports, 10, 67-71. http://dx.doi.org/10.1007/s11886-008-0013-5 |
| [7] | Flohr, T.G., et al. (2008) Image Reconstruction and Image Quality Evaluation for a Dual Source CT Scanner. Medical Physics, 35, 5882-5897. http://dx.doi.org/10.1118/1.3020756 |
| [8] | Lee, S.H., et al. (2008) Incidental Cardiac and Pericardial Abnormalities on Chest CT. Journal of Thoracic Imaging, 23, 216-226. http://dx.doi.org/10.1097/RTI.0b013e318166a485 |
| [9] | Burt,
J.R., et al. (2008) Incidental Findings on Cardiac Multidetector Row
Computed Tomography among Healthy Older Adults. Archives of Internal
Medicine, 168, 756-761. http://dx.doi.org/10.1001/archinte.168.7.756 |
| [10] | Manghat, N., et al. (2008) Imaging the Heart Valves Using ECG-Gated 64-Detector Row Cardiac CT. The British Journal of Radiology, 81, 275-290. http://dx.doi.org/10.1259/bjr/16301537 |
| [11] | Stolzman,
P., et al. (2008) Left Ventricular and Left Atrial Dimensions and
Volumes, Comparison Between Dual-Source CT and Echocardiography.
Investigative Radiology, 43, 284-289. http://dx.doi.org/10.1097/RLI.0b013e3181626853 |
| [12] | Mahlon, M. and Yoon, H.C. (2007) CT Angiography of the Superior Vena Cava: Normative Values and Implications for Central Venous Catheter Position. Journal of Vascular and Interventional Radiology, 18, 1106-1110. http://dx.doi.org/10.1016/j.jvir.2007.06.002 |
| [13] | Gade, C., et al. (2007) Comprehensive Evaluation of Atrial Septal Defects in Individuals Undergoing Percutaneous Repair by 64-Detector Row Computed Tomography. The International Journal of Cardiovascular Imaging, 23, 397-404. http://dx.doi.org/10.1007/s10554-006-9149-9 |
| [14] | O’Brien, J., et al. (2007) Anatomy of the Heart at Multidetector CT: What the Radiologist Needs to Know. RadioGraphics, 27, 1569-1582. http://dx.doi.org/10.1148/rg.276065747 |
| [15] | Stolzmann,
P., et al. (2008) Reference Values for Quantitative Left Ventricular
and Left Atrial Measurements in Cardiac Computed Tomography. European
Radiology, 18, 1625-1634. http://dx.doi.org/10.1007/s00330-008-0939-4 eww150120lx |
评论
发表评论