跳至主要内容

Comparison of Clinical and Radiographic Changes after Bryan Disc Arthroplasty versus ACDF: A 60-Month Follow-Up on 120 Patients

Read  full  paper  at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=53585#.VMnhfyzQrzE

ABSTRACT
Background: Artificial cervical disc replacement has become an option for cervical radiculopathy. Previous studies have evaluated the efficacy of this alternative without the scientific rigor of a concurrent control population in oriental patients for long-term follow-up. Objective: Therefore, we asked whether the 1) clinical and 2) radiographic outcomes of Bryan cervical disc prosthesis were better than that of anterior cervical discectomy and fusion (ACDF) at single site, and whether the 3) occurrences of heterotopic ossifications (HOs) were associated to the function loss in the long-term follow-up. Methods: A total of 120 patients with cervical disc disease were randomly assigned to two groups (Bryan or ACDF), and 60-month follow-up is available for all the 120 patients. Clinical outcomes were assessed using Odom’s criteria, visual analogue pain scale (VAS) and Neck Disability Index (NDI). Radiographs were measured to determine the radiographic outcomes and occurrences of heterotopic ossifications (HOs). Results: The clinical outcomes are not significantly between the two groups (VAS, P = 0.7253; NDI, P = 0.5528). The radiographic outcome ofBryancervical disc prosthesis is better than that of ACDF group at the index level (P < 0.05). 36 (60%) patients ofBryangroup developed heterotopic ossification. But, there is not a significant association between HOs and the loss of movement at the replacement level. Conclusions: The Bryan artificial disc replacement compares favorably to ACDF for the treatment of patients with 1-level cervical disc disease. And theBryandisc may delay adjacent level degeneration by preserving preoperative kinematics at adjacent levels in oriental patients.
 
Cite this paper
Cao, F. , Liu, T. , Xu, Y. , Han, H. , Dong, R. and Feng, S. (2015) Comparison of Clinical and Radiographic Changes after Bryan Disc Arthroplasty versus ACDF: A 60-Month Follow-Up on 120 Patients. World Journal of Neuroscience, 5, 40-48. doi: 10.4236/wjns.2015.51005.
 
References
[1]Grob, D., Porchet, F., Kleinstück, F.S., Lattig, F. and Jeszenszky, D. (2010) A Comparison of Outcomes of Cervical Disc Arthroplasty and Fusion in Everyday Clinical Practice: Surgical and Methodological Aspects. European Spine Journal, 19, 297-306. http://dx.doi.org/10.1007/s00586-009-1194-3
 
[2]Garrido, B.J., Taha, T.A. and Sasso, R.C. (2010) Clinical Outcomes of Bryan Cervical Disc Arthroplasty—A Prospective, Randomized, Controlled, Single Site Trial with 48-Month Follow-Up. Journal of Spinal Disorders Techniques, 23, 367-371. http://dx.doi.org/10.1097/BSD.0b013e3181bb8568
 
[3]Vernon, H. and Mior, S. (1991) The Neck Disability Index: A Study of Reliability and Validity. Journal of Manipulative and Physiological Therapeutics, 14, 409-415.
 
[4]McAfee, P.C., Cunningham, B.W., Devine, J., Williams, E., Yu-Yahiro, J., et al. (2003) Classification of Heterotopic Ossification (HO) in Artificial Disk Replacement. Journal of Spinal Disorders Techniques, 16, 384-389. http://dx.doi.org/10.1097/00024720-200308000-00010
 
[5]Ahn, P.G., Kim, K.N., Moon, S.W. and Kim, K.S. (2009) Changes in Cervical Range of Motion and Sagittal Alignment in Early and Late Phases after Total Disc Replacement: Radiographic Follow-Up Exceeding 2 Years. Journal of Neurosurgery: Spine, 11, 688-695. http://dx.doi.org/10.3171/2009.7.SPINE0946
 
[6]Shim, C.S., Lee, S.H., Park, H.J., Kang, H.S. and Hwang, J.H. (2006) Early Clinical and Radiologic Outcomes of Cervical Arthroplasty with Bryan Cervical Disc Prosthesis. Journal of Spinal Disorders Techniques, 19, 465-470. http://dx.doi.org/10.1097/01.bsd.0000211235.76093.6b
 
[7]Leung, C., Casey, A.T., Goffin, J., Kehr, P. and Liebig, K. (2005) Clinical Significance of Heterotopic Ossification in Cervical Disc Replacement: A Prospective Multicenter Clinical Trial. Neurosurgery, 57, 759-763. http://dx.doi.org/10.1227/01.NEU.0000175856.31210.58
 
[8]Garrido, B.J., Taha, T.A. and Sasso, R.C. (2010) Clinical Outcomes of Bryan Cervical Disc Arthroplasty a Prospective, Randomized, Controlled, Single Site Trial with 48-Month Follow-Up. Journal of Spinal Disorders Techniques, 23, 367-371. http://dx.doi.org/10.1097/BSD.0b013e3181bb8568
 
[9]Singh, K., Phillips, F.M., Park, D.K., Pelton, M.A., An, H.S. and Goldberg, E.J. (2012) Factors Affecting Reoperations after Anterior Cervical Discectomy and Fusion within and outside of a Federal Drug Administration Investigational Device Exemption Cervical Disc Replacement Trial. Spine Journal, 12, 372-378. http://dx.doi.org/10.1016/j.spinee.2012.02.005
 
[10]Powell, J.W., Sasso, R.C., Metcalf, N.H., Anderson, P.A. and Hipp, J.A. (2010) Quality of Spinal Motion with Cervical Disk Arthroplasty Computer-Aided Radiographic Analysis. Journal of Spinal Disorders Techniques, 23, 89-95. http://dx.doi.org/10.1097/BSD.0b013e3181991413
 
[11]Kang, K.C., Lee, C.S., Han, J.H. and Chung, S.S. (2010) The Factors That Influence the Postoperative Segmental Range of Motion after Cervical Artificial Disc Replacement. The Spine Journal, 10, 689-696. http://dx.doi.org/10.1016/j.spinee.2010.04.016
 
[12]Heller, J.G., Sasso, R.C., Papadopoulos, S.M., Anderson, P.A. and Fessler, R.G. (2009) Comparison of BRYAN Cervical Disc Arthroplasty with Anterior Cervical Decompression and Fusion: Clinical and Radiographic Results of a Randomized, Controlled, Clinical Trial. Spine, 34, 101-107.
http://dx.doi.org/10.1097/BRS.0b013e31818ee263
 
[13]Kim, S.W., Limson, M.A., Kim, S.B., Arbatin, J.J. and Chang, K.Y. (2009) Comparison of Radiographic Changes after ACDF versus Bryan Disc Arthroplasty in Single and Bi-Level Cases. European Spine Journal, 18, 218-231. http://dx.doi.org/10.1007/s00586-008-0854-z
 
[14]Sasso, R.C., Best, N.M., Metcalf, N.H. and Anderson, P.A. (2008) Motion Analysis of Bryan Cervical Disc Arthroplasty versus Anterior Discectomy and Fusion: Results from a Prospective, Randomized, Multicenter, Clinical Trial. Journal of Spinal Disorders Techniques, 21, 393-399.
http://dx.doi.org/10.1097/BSD.0b013e318150d121              eww150129lx

评论

此博客中的热门博文

A Comparison of Methods Used to Determine the Oleic/Linoleic Acid Ratio in Cultivated Peanut (Arachis hypogaea L.)

Cultivated peanut ( Arachis hypogaea L.) is an important oil and food crop. It is also a cheap source of protein, a good source of essential vitamins and minerals, and a component of many food products. The fatty acid composition of peanuts has become increasingly important with the realization that oleic acid content significantly affects the development of rancidity. And oil content of peanuts significantly affects flavor and shelf-life. Early generation screening of breeding lines for high oleic acid content greatly increases the efficiency of developing new peanut varieties. The objective of this study was to compare the accuracy of methods used to classify individual peanut seed as high oleic or not high oleic. Three hundred and seventy-four (374) seeds, spanning twenty-three (23) genotypes varying in oil composition (i.e. high oleic (H) or normal/not high oleic (NH) inclusive of all four peanut market-types (runner, Spanish, Valencia and Virginia), were individually tested ...

Location Optimization of a Coal Power Plant to Balance Costs against Plant’s Emission Exposure

Fuel and its delivery cost comprise the biggest expense in coal power plant operations. Delivery of electricity from generation to consumers requires investment in power lines and transmission grids. Placing a coal power plant or multiple power plants near dense population centers can lower transmission costs. If a coalmine is nearby, transportation costs can also be reduced. However, emissions from coal plants play a key role in worsening health crises in many countries. And coal upon combustion produces CO 2 , SO 2 , NO x , CO, Metallic and Particle Matter (PM10 & PM2.5). The presence of these chemical compounds in the atmosphere in close vicinity to humans, livestock, and agriculture carries detrimental health consequences. The goal of the research was to develop a methodology to minimize the public’s exposure to harmful emissions from coal power plants while maintaining minimal operational costs related to electric distribution losses and coal logistics. The objective was...

Evaluation of the Safety and Efficacy of Continuous Use of a Home-Use High-Frequency Facial Treatment Appliance

At present, many home-use beauty devices are available in the market. In particular, many products developed for facial treatment use light, e.g., a flash lamp or a light-emitting diode (LED). In this study, the safety of 4 weeks’ continuous use of NEWA TM , a high-frequency facial treatment appliance, every alternate day at home was verified, and its efficacy was evaluated in Japanese individuals with healthy skin aged 30 years or older who complained of sagging of the facial skin.  Transepidermal water loss (TEWL), melanin levels, erythema levels, sebum secretion levels, skin color changes and wrinkle improvement in the facial skin were measured before the appliance began to be used (study baseline), at 2 and 4 weeks after it had begun to be used, and at 2 weeks after completion of the 4-week treatment period (6 weeks from the study baseline). In addition, data obtained by subjective evaluation by the subjects themselves on a visual analog scale (VAS) were also analyzed. Fur...