跳至主要内容

Experience with Miniaturized Cardiopulmonary Bypass in Cardiac Surgery: A Prospective Comparison of the NovoSCI Ready System to Off-Pump and Conventional Coronary Artery Bypass Grafting

Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=52444#.VJjCicCAM4

The major source of morbidity following cardiopulmonary bypass (CPB) is the systemic inflammatory response (SIRS response) which leads to multiple derangements in different organ systems. To combat this, miniaturized cardiopulmonary bypass circuits (MCPBC) have been created to lessen the inflammatory response to CPB. Here we examine early outcomes following coronary artery bypass grafting (CABG) using a MCPBC system compared to conventional bypass techniques at a single institution. Methods: 60 consecutive patients undergoing elective CABG were prospectively enrolled. Nine patients underwent coronary artery bypass grafting (CABG) with conventional CPB (cCABG), 33 underwent off-pump CABG (OPCAB), and the remaining 18 patients underwent CABG with a MCPBC system. Demographics and outcomes were compared between groups and statistical analyses applied. Results: No significant difference was observed in mortality between groups, with only one death reported in total. Morbidity was also low, totaling only 6.7%, with none occurring in the MCPBC group. The MCPBC group required less PRBC and total blood product transfusion than the cCABG and OPCABG groups (p = 0.05), but changes in PLT and Hct over time were not different between groups. Conclusions: The MCPBC system was shown to be comparable to conventional bypass and OPCABG in terms of postoperative complications and mortality. Furthermore, the MCPBC system had the advantage of a decreased transfusion requirement. Based on our preliminary observations, this mini-cardiopulmonary bypass circuit provides a safe alternative to conventional bypass techniques.
Cite this paper
Emerson, D. , Baldwin, D. , Pinales, M. , Greenberg, M. , Mattes, M. and Trachiotis, G. (2014) Experience with Miniaturized Cardiopulmonary Bypass in Cardiac Surgery: A Prospective Comparison of the NovoSCI Ready System to Off-Pump and Conventional Coronary Artery Bypass Grafting. World Journal of Cardiovascular Surgery, 4, 232-238. doi: 10.4236/wjcs.2014.412034
 

[1] Gibbon Jr., J.H. (1954) Application of a Mechanical Heart and Lung Apparatus to Cardiac Surgery. Minnesota Medicine, 37, 171-185.
[2] Edwards, F.H., Clark, R.E. and Schwartz, M. (1994) Coronary Artery Bypass Grafting: The Society of Thoracic Surgeons National Database Experience. The Annals of Thoracic Surgery, 57, 12-19.
http://dx.doi.org/10.1016/0003-4975(94)90358-1
[3] Fitzgibbon, G.M., Kafka, H.P., Leach, A.J., Keon, W.J., Hooper, G.D. and Burton, J.R. (1996) Coronary Bypass Graft Fate and Patient Outcome: Angiographic Follow-Up of 5,065 Grafts Related to Survival and Reoperation in 1,388 Patients during 25 Years. Journal of the American College of Cardiology, 28, 616-626.
http://dx.doi.org/10.1016/0735-1097(96)00206-9
[4] Liebold, A., Keyl, C. and Birnbaum, D.E. (1999) The Heart Produces but the Lungs Consume Proinflammatory Cytokines Following Cardiopulmonary Bypass. European Journal Cardio-Thoracic Surgery, 15, 340-345.
http://dx.doi.org/10.1016/S1010-7940(99)00038-X
[5] Wendel, H.P. and Ziemer, G. (1999) Coating-Techniques to Improve the Hemocompatibility of Artificial Devices Used for Extracorporeal Circulation. European Journal Cardio-Thoracic Surgery, 16, 342-350.
http://dx.doi.org/10.1016/S1010-7940(99)00210-9
[6] Kirklin, J.K., Westaby, S., Blackstone, E.H., Kirklin, J.W., Chenoweth, D.E. and Pacifico, A.D. (1983) Complement and the Damaging Effects of Cardiopulmonary Bypass. The Journal of Thoracic and Cardiovascular Surgery, 86, 845-857.
[7] Paparella, D., Yau, T.M. and Young, E. (2002) Cardiopulmonary Bypass Induced Inflammation: Pathophysiology and Treatment. An Update. European Journal Cardio-Thoracic Surgery, 21, 232-244.
http://dx.doi.org/10.1016/S1010-7940(01)01099-5
[8] Puskas, J.D. and Steele, M. (2007) Would You Like Some Cardiopulmonary Bypass with your Coronary Revascularization? Circulation, 116, 1756-1758.
http://dx.doi.org/10.1161/CIRCULATIONAHA.107.733089
[9] Wiesenack, C., Liebold, A., Philipp, A., Ritzka, M., Koppenberg, J., Birnbaum, D.E. and Keyl, C. (2004) Four Years’ Experience with a Miniaturized Extracorporeal Circulation System and Its Influence on Clinical Outcome. Artificial Organs, 28, 1082-1088.
http://dx.doi.org/10.1111/j.1525-1594.2004.00030.x
[10] Sakwa, M.P., Emery, R.W., Shannon, F.L., Altshuler, J.M., Mitchell, D., Zwada, D. and Holter, A.R. (2009) Coronary Artery Bypass Grafting with a Minimized Cardiopulmonary Bypass Circuit: A Prospective, Randomized Trial. The Journal of Thoracic and Cardiovascular Surgery, 137, 481-485.
http://dx.doi.org/10.1016/j.jtcvs.2008.08.057
[11] Remadi, J.P., Marticho, P., Butoi, I., Rakotoarivelo, Z., Trojette, F., Benamar, A., Beloucif, S., Foure, D. and Poulain, H.J. (2004) Clinical Experience with the Mini-Extracorporeal Circulation System: An Evolution or a Revolution? The Annals of Thoracic Surgery, 77, 2172-2175.
http://dx.doi.org/10.1016/S0003-4975(03)00977-9
[12] Liebold, A., Khosravi, A., Westphal, B., Skrabal, C., Choi, Y.H., Stamm, C., Kaminski, A., Alms, A., Birken, T., Zurakowski, D. and Steinhoff, G. (2006) Effect of Closed Minimized Cardiopulmonary Bypass on Cerebral Tissue Oxygenation and Microembolization. The Journal of Thoracic and Cardiovascular Surgery, 131, 268-276.
http://dx.doi.org/10.1016/j.jtcvs.2005.09.023
[13] Abdel-Rahman, U., Ozaslan, F., Risteski, P.S., Martens, S., Moritz, A., Al Daraghmeh, A., Keller, H. and Wimmer-Greinecker, G. (2005) Initial Experience with a Minimized Extracorporeal Bypass System: Is There a Clinical Benefit? The Annals of Thoracic Surgery, 80, 238-243.
http://dx.doi.org/10.1016/j.athoracsur.2005.02.032
[14] Beghi, C., Nicolini, F., Agostinelli, A., Borrello, B., Budillon, A.M., Bacciottini, F., Friggeri, M., Costa, A., Belli, L., Battistelli, L. and Gherli, T. (2006) Mini-Cardiopulmonary Bypass System: Results of a Prospective Randomized Study. The Annals of Thoracic Surgery, 81, 1396-400.
http://dx.doi.org/10.1016/j.athoracsur.2005.10.015
[15] Balachandran, S., Cross, M.H., Karthikeyan, S., Mulpur, A., Hansbro, S.D. and Hobson, P. (2002) Retrograde Autologous Priming of the Cardiopulmonary Bypass Circuit Reduces Blood Transfusion after Coronary Artery Surgery. The Annals of Thoracic Surgery, 73, 1912-1918.
http://dx.doi.org/10.1016/S0003-4975(02)03513-0
[16] Hsu, L.C. (1997) Biocompatibility in Cardiopulmonary Bypass. Journal of Cardiothoracic and Vascular Anesthesia, 11, 376-382.
http://dx.doi.org/10.1016/S1053-0770(97)90108-7
[17] Palatianos, G.M., Foroulis, C.N., Vassili, M.I., Astras, G., Triantafillou, K., Papadakis, E., Lidoriki, A.A., Iliopoulou, E. and Melissari, E.N. (2003) A Prospective, Double-Blind Study on the Efficacy of the Bioline Surface-Heparinized Extracorporeal Perfusion Circuit. The Annals of Thoracic Surgery, 76, 129-135.
http://dx.doi.org/10.1016/S0003-4975(03)00338-2
[18] Ovrum, E., Mollnes, T.E., Fosse, E., Holen, E.A., Tangen, G., Abdelnoor, M., Ringdal, M.A., Oystese, R. and Venge, P. (1995) Complement and Granulocyte Activation in Two Different Types of Heparinized Extracorporeal Circuits. The Journal of Thoracic and Cardiovascular Surgery, 110, 1623-1632.
http://dx.doi.org/10.1016/S0022-5223(95)70023-4
[19] Fromes, Y., Gaillard, D., Ponzio, O., Chauffert, M., Gerhardt, M.F., Deleuze, P. and Bical, O.M. (2002) Reduction of the Inflammatory Response Following Coronary Bypass Grafting with Total Minimal Extracorporeal Circulation. European Journal Cardio-Thoracic Surgery, 22, 527-533.
http://dx.doi.org/10.1016/S1010-7940(02)00372-X
[20] Koch, C.G., Li, L., Duncan, A.I., Mihaljevic, T., Cosgrove, D.M., Loop, F.D., Starr, N.J. and Blackstone, E.H. (2006) Morbidity and Mortality Risk Associated with Red Blood Cell and Blood-Component Transfusion in Isolated Coronary Artery Bypass Grafting. Critical Care Medicine, 34, 1608-1616.
http://dx.doi.org/10.1097/01.CCM.0000217920.48559.D8
[21] Koch, C.G., Li, L., Duncan, A.I., Mihaljevic, T., Loop, F.D., Starr, N.J. and Blackstone, E.H. (2006) Transfusion in Coronary Artery Bypass Grafting Is Associated with Reduced Long-Term Survival. The Annals of Thoracic Surgery, 81, 1650-1657.
http://dx.doi.org/10.1016/j.athoracsur.2005.12.037
[22] Fromes, Y., Gaillard, D., Ponzio, O., Chauffert, M., Gerhardt, M.F., Deleuze, P. and Bical, O.M. (2002) Reduction of the Inflammatory Response Following Coronary Bypass Grafting with Total Minimal Extracorporeal Circulation. European Journal Cardio-Thoracic Surgery, 22, 527-533.
http://dx.doi.org/10.1016/S1010-7940(02)00372-X
[23] Harling, L., Warren, O.J., Martin, A., Kemp, P.R., Evans, P.C., Darzi, A. and Athanasiou, T. (2011) Do Miniaturized Extracorporeal Circuits Confer Significant Clinical Benefit without Compromising Safety? A Meta-Analysis of Randomized Controlled Trials. ASAIO Journal, 57, 141-151.
http://dx.doi.org/10.1097/MAT.0b013e318209d63b
[24] Formica, F., Broccolo, F., Martino, A., Sciucchetti, J., Giordano, V., Avalli, L., Radaelli, G., Ferro, O., Corti, F., Cocuzza, C. and Paolini, G. (2009) Myocardial Revascularization with Miniaturized Extracorporeal Circulation versus Off Pump: Evaluation of Systemic and Myocardial Inflammatory Response in a Prospective Randomized Study. The Journal of Thoracic and Cardiovascular Surgery, 137, 1206-1212.
http://dx.doi.org/10.1016/j.jtcvs.2008.09.074              eww141223lx

评论

此博客中的热门博文

A Comparison of Methods Used to Determine the Oleic/Linoleic Acid Ratio in Cultivated Peanut (Arachis hypogaea L.)

Cultivated peanut ( Arachis hypogaea L.) is an important oil and food crop. It is also a cheap source of protein, a good source of essential vitamins and minerals, and a component of many food products. The fatty acid composition of peanuts has become increasingly important with the realization that oleic acid content significantly affects the development of rancidity. And oil content of peanuts significantly affects flavor and shelf-life. Early generation screening of breeding lines for high oleic acid content greatly increases the efficiency of developing new peanut varieties. The objective of this study was to compare the accuracy of methods used to classify individual peanut seed as high oleic or not high oleic. Three hundred and seventy-four (374) seeds, spanning twenty-three (23) genotypes varying in oil composition (i.e. high oleic (H) or normal/not high oleic (NH) inclusive of all four peanut market-types (runner, Spanish, Valencia and Virginia), were individually tested ...

Location Optimization of a Coal Power Plant to Balance Costs against Plant’s Emission Exposure

Fuel and its delivery cost comprise the biggest expense in coal power plant operations. Delivery of electricity from generation to consumers requires investment in power lines and transmission grids. Placing a coal power plant or multiple power plants near dense population centers can lower transmission costs. If a coalmine is nearby, transportation costs can also be reduced. However, emissions from coal plants play a key role in worsening health crises in many countries. And coal upon combustion produces CO 2 , SO 2 , NO x , CO, Metallic and Particle Matter (PM10 & PM2.5). The presence of these chemical compounds in the atmosphere in close vicinity to humans, livestock, and agriculture carries detrimental health consequences. The goal of the research was to develop a methodology to minimize the public’s exposure to harmful emissions from coal power plants while maintaining minimal operational costs related to electric distribution losses and coal logistics. The objective was...

Evaluation of the Safety and Efficacy of Continuous Use of a Home-Use High-Frequency Facial Treatment Appliance

At present, many home-use beauty devices are available in the market. In particular, many products developed for facial treatment use light, e.g., a flash lamp or a light-emitting diode (LED). In this study, the safety of 4 weeks’ continuous use of NEWA TM , a high-frequency facial treatment appliance, every alternate day at home was verified, and its efficacy was evaluated in Japanese individuals with healthy skin aged 30 years or older who complained of sagging of the facial skin.  Transepidermal water loss (TEWL), melanin levels, erythema levels, sebum secretion levels, skin color changes and wrinkle improvement in the facial skin were measured before the appliance began to be used (study baseline), at 2 and 4 weeks after it had begun to be used, and at 2 weeks after completion of the 4-week treatment period (6 weeks from the study baseline). In addition, data obtained by subjective evaluation by the subjects themselves on a visual analog scale (VAS) were also analyzed. Fur...