Respiratory Volume Monitoring to Assess the Effect of Airway Maneuvers on Ventilation during Upper Endoscopy
Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=51320#.VGRvPmfHRK0
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=51320#.VGRvPmfHRK0
Author(s)
Introduction: Propofol use during endoscopic
procedures has become increasingly popular and assessing and maintaining
airway patency is a significant challenge. Anesthesiologists often use
airway maneuvers to maintain airway patency and ventilation during
procedural sedation. A novel, non-invasive, Respiratory Volume Monitor
(RVM) that provided continuous, real-time measurements of minute
ventilation (MV), tidal volume (TV) and respiratory rate (RR) was used
to monitor respiratory performance before, during, and after endoscopic
procedures, quantify MV changes before and after airway maneuvers, and
to quantify propofol-induced respiratory depression. Methods: RVM traces
were obtained from 25 patients undergoing sedation for endoscopic
procedures. Airway maneuvers were performed in 19/25 patients. All 25
patients received propofol as the primary sedative. Results: Forty-five
airway maneuvers were performed. During these maneuvers, all respiratory
parameters increased relative to pre-maneuver levels. On average, MV
increased by 24% ± 5% (mean ± SEM), TV 14% ± 5% and RR: 17% ± 6%. The
cohort average MVBASELINE was 9.5 ± 0.7 L/min (TV = 670 ± 60 ml, RR = 15
± 0.7). Following propofol MV decreased transiently, reaching nadir
five minutes after the last dose of propofol at 82% ± 10% of baseline
(MV = 7.5 ± 1.0 L/min). The reduction in MV was driven by reduction in
TV, not RR. Conclusions: Data demonstrated that RVM was able to track
changes in ventilation and was able to quantify respiratory changes
following airway maneuvers. All patients had a significant reduction in
ventilatory volumes after propofol. Five minutes after the last dose of
propofol, MV and TV were significantly reduced while RR was not,
suggesting that monitoring respiratory rate alone was not a sufficient
indicator of respiratory status.
KEYWORDS
Cite this paper
Holley, K. , Mathews, D. , Ladd, D. , Campana, L.
and Schapiro, H. (2014) Respiratory Volume Monitoring to Assess the
Effect of Airway Maneuvers on Ventilation during Upper Endoscopy. Open Journal of Anesthesiology, 4, 281-290. doi: 10.4236/ojanes.2014.411041.
| [1] |
Seeff, L.C., Richards, T.B.,
Shapiro, J.A., et al. (2004) How Many Endoscopies Are Performed for
Colorectal Cancer Screening? Results from CDC’s Survey of Endoscopic
Capacity. Gastroenterology, 127, 1670-1677. http://dx.doi.org/10.1053/j.gastro.2004.09.051 |
| [2] |
American Society for
Gastrointestinal Surgery (2002) Guidelines for the Use of Deep Sedation
and Anesthesia for GI Endoscopy. Gastrointestinal Endoscopy, 56,
613-617. http://dx.doi.org/10.1016/S0016-5107(02)70104-1 |
| [3] |
Mackenzie, N. and Grant, I.S.
(1987) Propofol for Intravenous Sedation. Anaesthesia, 42, 3-6. http://dx.doi.org/10.1111/j.1365-2044.1987.tb02936.x |
| [4] |
Faulx, A.L., Vela, S., Das, A.,
et al. (2005) The Changing Landscape of Practice Patterns Regarding
Unsedated Endoscopy and Propofol Use: A National Web Survey.
Gastrointestinal Endoscopy, 62, 9-15. http://dx.doi.org/10.1016/S0016-5107(05)00518-3 |
| [5] |
Hillman, D.R., Platt, P.R. and
Eastwood, P.R. (2003) Upper Airway during Anesthesia. British Journal of
Anaesthesia, 91, 31-39. http://dx.doi.org/10.1093/bja/aeg126 |
| [6] |
Taylor, M.B., Grounds, R.M.,
Mulrooney, P.D. and Morgan, M. (1986) Ventilatory Effects of Propofol
during Induction of Anaesthesia. Anaesthesia, 41, 816-820. http://dx.doi.org/10.1111/j.1365-2044.1986.tb13123.x |
| [7] | Goodman, N.W., Black, A.M.S. and Carter, J.A. (1987) Some Ventilatory Effects of Propofol as a Sole Anaesthetic Agent. British Journal of Anaesthesia, 59, 1497-1503. |
| [8] | Cote, G.A., Hovis, R.M., Ansstas, M.A., et al. (2010) Incidence of Sedation-Related Complications with Propofol Use during Advanced Endoscopic Procedures. Clinical Gasterenterology and Hepatology, 8, 137-142. |
| [9] |
Overdyk, F.J., Carter, R.,
Maddox, R.R., Callura, J., Herrin, A.E., et al. (2007) Continuous
Oximetry/Capnometry Monitoring Reveals Frequent Desaturation and
Bradypnea during Patient-Controlled Analgesia. Anesthesia &
Analgesia, 105, 412-418. http://dx.doi.org/10.1213/01.ane.0000269489.26048.63 |
| [10] |
Voscopoulos, C., Brayanov, J.,
Ladd, D., Lalli, M., Panasyuk, A., et al. (2013) Evaluation of a Novel
Non-Invasive Respiration Monitor Providing Continuous Measurement of
Minute Ventilation in Ambulatory Subjects in a Variety of Clinical
Scenarios. Anesthesia & Analgesia, 117, 91-100. http://dx.doi.org/10.1213/ANE.0b013e3182918098 |
| [11] |
Du Bois, D. and Du Bois, E.F.
(1916) A Formula to Estimate the Approximate Surface Area if Height and
Weight Be Known. Archives of Internal Medicine, 17, 863-871. http://dx.doi.org/10.1001/archinte.1916.00080130010002 |
| [12] |
American Academy of Respiratory
Care Protocol Committee (2003) AARC: Adult Mechanical Ventilator
Protocols. http://www.aarc.org/resources/protocol_resources/documents/general_vent.pdf |
| [13] |
Metzner, J. and Domino, K.
(2011) Risk of Anesthesia Care in Remote Locations. APSF Newsletter. http://www.apsf.org/newsletters/html/2011/spring/06_remotelocation.htm |
| [14] |
American Society of Anesthesiologists (2010) Standards for Basic Anesthetic Monitoring. http://www.asahq.org/For-Healthcare-Professionals/Standards- Guidelines-and-Statements.aspx |
| [15] |
Mimoz, O., Bernard, T., Gaucher,
A., Fransca, D. and Debaene, B. (2012) Accuracy of Respiratory Rate
Monitoring Using a Non-Invasive Acoustic Method after General
Anaesthesia. British Journal of Anaesthesia, 108, 872-875. http://dx.doi.org/10.1093/bja/aer510 |
| [16] |
Ramsay, M., Usman, M., Lagow,
E., Mendoza, M., Untalan, E., et al. (2013) The Accuracy, Precision and
Reliability of Measuring Ventilatory Rate and Detecting Ventilatory
Pause by Rainbow Acoustic Monitoring and Capnometry. Anesthesia and
Analgesia, 117, 69-75. http://dx.doi.org/10.1213/ANE.0b013e318290c798 eww141113lx |
评论
发表评论