Reversible Immobilization of Chelating Affinity Surfactants on Reversed Phase Adsorbents for Protein and Peptide Separations under Metal Affinity Chromatography
Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=50437#.VD9CHFfHRK0
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=50437#.VD9CHFfHRK0
Author(s)
Alkyl-bound silica
was modified using chelating surfactants and the resulting adsorbent was used
in immobilized metal affinity chromatography of proteins and peptides. Brij-76,
a non-ionic amphiphilic surfactant with an alkyl moiety and an ethylene oxide
chain, was reversible adsorbed to alkyl silica (C18). The hydroxyl
group at the end of the ethylene oxide chain was chemically modified previously
with an iminodiacetate functionality as chelating agent of transitional metal
ions. Cu(II) was studied as immobilized ion for the adsorption of peptides and
proteins. Three chromatographic supports were prepared having different Cu(II)
capacities. For a low Cu(II) capacity case, the generated adsorbent behaved as
a controlled access media preventing the adsorption of large molecular weight
proteins, such as BSA, while small peptides, such as Angiotensin III, or amino
acids could be retained. For a medium and high Cu(II) capacity, the synthesized
adsorbent no longer behaved as a controlling access media and all molecules in
this study, either large or small, were retained by the immobilized ion.
Nonetheless, most of the BSA was strongly retained by the system and a pH
change did not remove any of the adsorbed BSA while the small molecules were
removed by the same pH change.
Cite this paper
González-Ortega, O. and Guzmán, R. (2014)
Reversible Immobilization of Chelating Affinity Surfactants on Reversed
Phase Adsorbents for Protein and Peptide Separations under Metal
Affinity Chromatography. American Journal of Analytical Chemistry, 5, 932-944. doi: 10.4236/ajac.2014.514101.
| [1] |
Regnier, F.E. (1987) HPLC of
Biological Macromolecules: The First Decade. Chromatographia, 24,
241-251. http://dx.doi.org/10.1007/BF02688486 |
| [2] |
Riordain, C.O., Barron, L.,
Nesterenko, E., Nesterenko, P.N. and Paull, B. (2006) Double Gradient
Ion Chromatography Using Short Monolithic Columns Modified with a Long
Chained Zwitterionic Carboxybetaine Surfactant. Journal of
Chromatography A, 1109, 111-119. http://dx.doi.org/10.1016/j.chroma.2006.01.002 |
| [3] | Kelmers, A.D., Novelli, G.D. and Stulberg, M.P. (1965) Separation of Transfer Ribonucleic Acids by Reverse Phase Chromatography. Journal of Biological Chemistry, 240, 3979-3983. |
| [4] |
Weiss, J.F., Pearson, R.L. and
Kelmers, A.D. (1968) Two Additional Reversed-Phase Chromatographic
Systems for the Separation of Transfer Ribonucleic Acids and Their
Application to the Preparation of Two Formylmethionine and a Valine
Transfer Ribonucleic Acid from Escherichia coli B. Biochemistry, 7,
3479-3487. http://dx.doi.org/10.1021/bi00850a024 |
| [5] |
Bischoff, R., Graeser, E. and
McLaughlin, L.W. (1983) tRNA Separation by High-Performance Liquid
Chromatography Using an Aggregate of Ods-Hypersil and
Trioctylmethylammonium Chloride. Journal of Chromatography, 257,
305-315. http://dx.doi.org/10.1016/S0021-9673(01)88186-3 |
| [6] |
Bischoff, R. and McLaughlin,
L.W. (1985) Isolation of Specific tRNAs Using an Ionic-Hydrophobic
Mixed-Mode Chromatographic Matrix. Analytical Biochemistry, 151,
526-533. http://dx.doi.org/10.1016/0003-2697(85)90215-5 |
| [7] |
Chang, J.P. (1984) Effect of
Surfactants on the Separation of Proteins by Reversed-Phase
High-Performance Liquid Chromatography. I. Non-Ionic Surfactants
(Tween). Journal of Chromatography, 317, 157-163. http://dx.doi.org/10.1016/S0021-9673(01)91655-3 |
| [8] |
Torres, J.L., Guzman, R.,
Carbonell, R.G. and Kilpatrick, P.K. (1988) Affinity Surfactants as
Reversibly Bound Ligands for High-Performance Affinity Chromatography.
Analytical Biochemistry, 171, 411-418. http://dx.doi.org/10.1016/0003-2697(88)90507-6 |
| [9] |
Guzman, R., Torres, J.L.,
Carbonell, R.G. and Kilpatrick, P.K. (1989) Water-Soluble Nonionic
Surfactants for Affinity Bioseparations. Biotechnology and
Bioengineering, 33, 1267-1276. http://dx.doi.org/10.1002/bit.260331007 |
| [10] |
Keller, D.E., Torres, J.L.,
Carbonell, R.G. and Kilpatrick, P.K. (1989) Reversible Conversion of
Octadecyl-Bonded Silica to Ion-Exchange Surfaces for Protein
Separations. Analytical Biochemistry, 176, 191-198. http://dx.doi.org/10.1016/0003-2697(89)90292-3 |
| [11] |
Sing, Y.L.K., Algiman, E.,
Kroviarski, Y., Massot, C., Dhermy, D. and Bertrand, O. (1991)
Modification of Reversed-Phase Column with Dyed Surfactants. Preparation
of Mechanically Resistant Efficient Immobilized Dyes for Protein
Purification. Journal of Chromatography A, 558, 43-54. http://dx.doi.org/10.1016/0021-9673(91)80110-3 |
| [12] |
Desilets, C.P., Rounds, M.A. and
Regnier, F.E. (1191) Semipermeable-Surface Reversed-Phase Media for
High-Performance Liquid Chromatography. Journal of Chromatography A,
544, 25-39. http://dx.doi.org/10.1016/S0021-9673(01)83976-5 |
| [13] |
Sing, Y.L.K., Kroviarski, Y.,
Cochet, S., Dhermy, D. and Bertrand, O. (1992) High-Performance
Hydrophobic Interaction Chromatography of Proteins on Reversed-Phase
Supports Coated with Non-Ionic Surfactants of Polyoxyethylene Type
Purification of a Fungal Aspartic Proteinase. Journal of Chromatography
A, 598, 181-187. http://dx.doi.org/10.1016/0021-9673(92)85046-V |
| [14] |
Gombotz, W.R., Guanghui, W.,
Horbett, T.A. and Hoffman, A.S. (1991) Protein Adsorption to
Poly(ethylene Oxide) Surfaces. Journal of Biomedical Materials Research,
25, 1547-1562. http://dx.doi.org/10.1002/jbm.820251211 |
| [15] |
Porath, J., Carlsson, J.,
Olsson, I. and Belfrage, G. (1975) Metal Chelate Affinity
Chromatography, a New Approach to Protein Fractionation. Nature, 258,
598-599. http://dx.doi.org/10.1038/258598a0 |
| [16] |
Gutiérrez, R., del Valle, E.M.M.
and Galán, M.A. (2007) Immobilized Metal-Ion Affinity Chromatography:
Status and Trends. Separation and Purification Reviews, 36, 71-111. http://dx.doi.org/10.1080/15422110601166007 |
| [17] |
Ho, C., Limberis, L., Caldwell,
K.D. and Stewart, R.J. (1998) A Metal-Chelating Pluronic for
Immobilization of Histidine-Tagged Proteins at Interfaces:
Immobilization of Firefly Luciferase on Polystyrene Beads. Langmuir, 14,
3889-3894. http://dx.doi.org/10.1021/la980148k |
| [18] |
Bradford, M.M. (1976) A Rapid
and Sensitive Method for the Quantitation of Microgram Quantities of
Protein Utilizing the Principle of Protein-Dye Binding. Analytical
Biochemistry, 72, 248-254. http://dx.doi.org/10.1016/0003-2697(76)90527-3 |
| [19] | Berthod, A. and Coque, C.G.A. (2000) Micellar Liquid Chromatography. Marcel Dekker, Inc., New York. |
| [20] |
Borgerding, M.F., Hinze, W.L.,
Stafford, L.D., Fulp, G.W. and Hamlin Jr., W.C. (1989) Investigations of
Stationary Phase Modification by the Mobile Phase Surfactant in
Micellar Liquid Chromatography. Analytical Chemistry, 61, 1353-1358. http://dx.doi.org/10.1021/ac00188a011 |
| [21] |
Borgerding, M.F., Williams,
R.L., Hinze, W.L. and Quina, F.H. (1989) New Perspectives in Micellar
Liquid Chromatography. Journal of Liquid Chromatography, 12, 1367-1406. http://dx.doi.org/10.1080/01483918908049512 |
| [22] |
Rosen, M.J. (2004) Surfactants
and Interfacial Phenomena. John Wiley & Sons, Inc., Hoboken. http://dx.doi.org/10.1002/0471670561 |
| [23] |
Smith, M.C., Furman, T.C. and
Pidgeon, C. (1987) Immobilized Iminodiacetic Acid Metal Peptide
Complexes. Identification of Chelating Peptide Purification Handles for
Recombinant Proteins. Inorganic Chemistry, 26, 1965-1969. http://dx.doi.org/10.1021/ic00259a030 |
| [24] |
Morra, M. (2000) On the
Molecular Basis of Fouling Resistance. Journal of Biomaterials Science,
Polymer Edition, 11, 547-569. http://dx.doi.org/10.1163/156856200743869 |
| [25] |
Szleifer, I. (1997) Protein
Adsorption on Surfaces with Grafted Polymers: A Theoretical Approach.
Biophysical Journal, 72, 595-612. http://dx.doi.org/10.1016/S0006-3495(97)78698-3 |
| [26] |
Halperin, A. (1999) Polymer
Brushes That Resist Adsorption of Model Proteins: Design Parameters.
Langmuir, 15, 2525-2533. http://dx.doi.org/10.1021/la981356f |
| [27] |
Wattendorf, U. and Merkle, H.P.
(2008) PEGylation as a Tool for the Biomedical Engineering of Surface
Modified Microparticles. Journal of Pharmaceutical Sciences, 97,
4655-4669. http://dx.doi.org/10.1002/jps.21350 |
| [28] |
Sulkowski, E. (1985) Purification of Proteins by IMAC. Trends in Biotechnology, 3, 1-7. http://dx.doi.org/10.1016/0167-7799(85)90068-X |
| [29] |
Sharma, S. and Agarwal, G.P.
(2001) Interactions of Proteins with Immobilized Metal Ions: A
Comparative Analysis Using Various Isotherm Models. Analytical
Biochemistry, 288, 126-140. http://dx.doi.org/10.1006/abio.2000.4894 |
| [30] | Cross, J. (1987) Nonionic Surfactants. Chemical Analysis. Marcel Dekker, Inc., New York. |
| [31] | Holmberg, K., Jonsson, B., Kronberg, B. and Lindman, B. (2003) Surfactants and Polymers in Aqueous Solutions. John Wiley & Sons, West Sussex. |
| [32] |
Berthod, A., Tomer, S. and
Dorsey, J.G. (2001) Polyoxyethylene Alkyl Ether Nonionic Surfactants:
Physicochemical Properties and Use for Cholesterol Determination in
Food. Talanta, 55, 69-83. http://dx.doi.org/10.1016/S0039-9140(01)00395-2 |
| [33] |
Belew, M. and Porath, J. (1991)
Immobilized Metal Ion Affinity Chromatography. Effect of Solute
Structure, Ligand Density and Salt Concentration on the Retention of
Peptides. Journal of Chromatography A, 516, 333-354. http://dx.doi.org/10.1016/S0021-9673(01)89275-X eww141016lx |
评论