This paper examines the use of corrosion inhibitors
in order to protect the reinforcement of concrete. For this purpose
mortar specimens were constructed with or without corrosion inhibitors
and were partially immersed in sodium chloride. Corrosion inhibitors
were used as admixture into concrete and were sprayed on the external
surface of mortar specimens. In all mortar specimens, electric junction
between reinforcements was achieved. The methods that were used for the
evaluation of the reinforcement corrosion in concrete, included
half-cell potential measurements, polarization curves of reinforced
rebars and mass loss of the reinforcement. Finally, the durability of
concrete after the use of corrosion inhibitors was also examined.
KEYWORDS
Cite this paper
Zacharopoulou, A. , Zacharopoulou, E. and Batis, G.
(2014) Protection Systems for Reinforced Concrete with Corrosion
Inhibitors. Open Journal of Metal, 4, 86-92. doi: 10.4236/ojmetal.2014.44010.
| [1] |
Batis, G., Kouloumbi, N. and
Pantazopoulou, P. (2005) Corrosion Protection of Steel in Pumice
Lightweight Mortar by Coatings. Cement and Concrete Composites, 27,
261-267. http://dx.doi.org/10.1016/j.cemconcomp.2004.02.015 |
| [2] |
Kouloumbi, N. and Batis, G.
(1992) Chloride Corrosion of Steel Rebars in Mortars with Fly Ash
Admixtures. Cement and Concrete Composites, 14, 199-207. http://dx.doi.org/10.1016/0958-9465(92)90014-M |
| [3] | Broomfield, J. (1997) Corrosion of Steel in Concrete Understanding, Investigation and Repair. E & FN SPOK, London, 16-21. |
| [4] |
Basheer, P.A.M., Basheer, L.,
Cleland, D.J. and Long, A.E. (1997) Surface Treatments for Concrete:
Assessment Methods and Reported Performance. Construction and Building
Materials, 7-8, 413-429.
http://dx.doi.org/10.1016/S0950-0618(97)00019-6 |
| [5] |
Ibrahim, M., Al-Gahtani, A.S.
and Maslehuddin, M. (1999) Use of Surface Treatment Materials to Improve
Concrete Durability. Journal of Materials in Civil Engineering, 11,
36-40.
http://dx.doi.org/10.1061/(ASCE)0899-1561(1999)11:1(36) |
| [6] | Brown, M.C. (1999) Assessment of Commercial Corrosion Inhibiting Admixtures for Reinforced Concrete. Virginia Polytechnic Institute, Virginia. |
| [7] | ELOT 142-37, Hellenic Organization of Standardization, Athens. |
| [8] | Swamy, R.N., Suryavanshi, A.K. and Tanikawa, S. (1998) Protective Ability of an Acrylic Based Surface Coating System against Chloride and Carbonation Penetration into Concrete. ACI Materials Journal, 95, 101-112. |
| [9] | ASTMC876-87 (1987) Standard Test Method for Half-Cell Potentials of Reinforcing Steel in Concrete. ASTM International, Philadelphia. |
| [10] | ASTM G59-97 (2009) Standard Test Method for Conducting Potentiodynamic Polarization Resistance Measurements. ASTM International, Philadelphia. |
| [11] | ISO/DIS 8407.3 (1986) Procedures for Removal of Corrosion Products from Corrosion Test Specimen. Genève. |
| [12] |
Gu, P. and Beaudoin, J. (1998)
Estimation of Steel Corrosion Rate in Reinforced Concrete by Means of
Equivalent Fittings of Impedance Spectra. Advances in Cement Research,
10, 43-56. http://dx.doi.org/10.1680/adcr.1998.10.2.43 |
| [13] |
Buenfeld, N.R. and Zhang, J.-Z.
(1998) Chloride Diffusion through Surface-Treated Mortar Specimens.
Cement and Concrete Research, 28, 665-674. http://dx.doi.org/10.1016/S0008-8846(98)00031-3 |
| [14] | DIN EN 7783-2 (1999) Determination and Classification of Water-Vapor Transmission Rate (Permeability). |
| [15] | Al-Amoudi, O.S.B., Maslehuddin, M., Lashari, A.N. and Almusallam, A.A. (2003) Effectiveness of Corrosion Inhibitors in Contaminated Concrete. Cement & Concrete Composites, 25, 439-449. |
| [16] | Fedrizzi, L., et al. (2005) Corrosion Inhibitors in Reinforced Concrete Structures Part 3—Migration of Inhibitors into Concrete. Cement and Concrete Research, 35, 551-561. eww141031lx |
评论
发表评论