Read full paper at:
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=48511#.VDtK_FfHRK0
http://www.scirp.org/journal/PaperInformation.aspx?PaperID=48511#.VDtK_FfHRK0
Author(s)
Trajectory of Energy Engineering, University of the Ciénega of Michoacán State, Sahuayo, México.
Trajectory of Energy Engineering, University of the Ciénega of Michoacán State, Sahuayo, México.
Trajectory of Energy Engineering, University of the Ciénega of Michoacán State, Sahuayo, México.
Trajectory of Educational Innovation, University of the Ciénega of Michoacán State, Sahuayo, México.
Trajectory of Energy Engineering, University of the Ciénega of Michoacán State, Sahuayo, México.
Trajectory of Energy Engineering, University of the Ciénega of Michoacán State, Sahuayo, México.
Trajectory of Energy Engineering, University of the Ciénega of Michoacán State, Sahuayo, México.
Trajectory of Educational Innovation, University of the Ciénega of Michoacán State, Sahuayo, México.
Trajectory of Energy Engineering, University of the Ciénega of Michoacán State, Sahuayo, México.
An equation model
for calculating the adiabatic temperature of the wet-bulb thermometer has been
obtained empirical fit through a meteorological database, specificly a trough
relative humidity and air temperature. A comparison of the results of
calculations with the use of this equation and from meteorological database was
made. The model deducted of the comparison is valid for a dry bulb temperature
range of 3°C to 35°C and for relative humidity percentage in a range of 7% to
97%. Normalized errors are less than 5.5%. It means a maximum variation of 0.55°C
from data. However, this variation from error represents only 3.6% of the data
sample. The equation model was satisfactory.
KEYWORDS
Cite this paper
Estrada-Jaramillo, M. , Vera-Romero, I. ,
Martínez-Reyes, J. , Ortíz-Soriano, A. and Barajas-Ledesma, E. (2014)
Empirical Model to Calculate the Thermodynamic Wet-Bulb Temperature of
Moist Air. Engineering, 6, 500-506. doi: 10.4236/eng.2014.69052.
| [1] |
Xuan, Y.M., Xiao, F., Niu, X.F.,
Huang, X. and Wang, S.W. (2012) Research and Application of Evaporative
Cooling in China: A Review (I)—Research. Renewable and Sustainable
Energy Reviews, 16, 3535-3546. http://dx.doi.org/10.1016/j.rser.2012.01.052 |
| [2] | Saudagar, R.T., Ingole, P.R., Mohod, T.R. and Choube, A.M. (2013) A Review of Emerging Technologies for Solar Air Conditioner. International Journal of Innovative Research in Science, Engineering and Technology, 2, 2356-2359. |
| [3] | Farzaneh, G.M. and Deymi, D.M. (2011) Effect of Various Inlet Air Cooling Methods on Gas Turbine Performance. Energy, 36, 1196-1205. http://dx.doi.org/10.1016/j.energy.2010.11.027 |
| [4] |
Rydstrand, M.C., Westermark,
M.O. and Bartlett, M.A. (2004) An Analysis of the Efficiency and Economy
of Humidified Gas Turbines in District Heating Applications. Energy,
29, 1945-1961. http://dx.doi.org/10.1016/j.energy.2004.03.023 |
| [5] | Jonssona, M. and Yan, J. (2005) Humidified Gas Turbines—A Review of Proposed and Implemented Cycles. Energy, 30, 1013-1078. http://dx.doi.org/10.1016/j.energy.2004.08.005 |
| [6] | American Society of Heating, Refrigerating and Air-Conditioning Engineers (2001) ASHRAE Fundamentals Handbook (SI). Chapter 6. Psychrometrics. 6.1-6.17. Atlanta. |
| [7] |
Alliston, C.W. and Wolfe, S.A.
(1973) Computation and Summary of Psychrometric Data from Dry Bulb and
Dew Point Temperatures. Agricultural Metereology, 11, 169-176. http://dx.doi.org/10.1016/0002-1571(73)90061-7 |
| [8] | Wilhelm, L.R. (1976) Numerical Calculation of Psychrometric Properties in SI Units. Transactions of the ASAE (American Society of Agricultural Engineers), 19, 318-321. National Agricultural Library Catalog (AGRICOLA), Beltsville. |
| [9] |
Singh, A.K., Singh, H., Singh,
S.P. and Sawhney, R.L. (2002) Numerical Calculation of Psychrometric
Properties on a Calculator. Building and Environment, 37, 415-419. http://dx.doi.org/10.1016/S0360-1323(01)00032-4 |
| [10] | Wang, D.C., Fang, W. and Fon, D.S. (2002) Development of a Digital Psychrometric Calculator Using MATLAB. Acta Hort, 578, 339-344. |
| [11] | Nelson, H.F. and Sauer, H.J. (2003) Thermodynamic Properties of Moist Air: -40 to 400°C. Proceedings of the 41st Aerospace Sciences Meeting and Exhibit, Reno Nevada, 6-9 January 2003, 1-11. |
| [12] | Anguiano, J.C., Ruíz, J.C., Alcántar, J.R., Vizcaino, I.V. and González, I.A. (2006) Basic Climatological Statistics of Michoacán State (Period 1961-2003). Technical Book No. 3. INIFAP, México. eww141013lx |
评论